Mitsubishi Electronics GOT1000 Portable Multimedia Player User Manual


 
22. FA TRANSPARENT FUNCTION
22.6 Personal Computer Side Setting
22 - 53
17
ROBOT
CONTROLLER
CONNECTION
18
CNC CONNECTION
19
GOT MULTI-DROP
CONNECTION
20
MULTIPLE-GT14, GT12,
GT11, GT10
CONNECTION FUNCTION
21
MULTI-CHANNEL
FUNCTION
22
FA TRANSPARENT
FUNCTION
22.6.4 Accessing PLC by
GX Configurator-QP
The following shows the procedure to set the FA
transparent function of GX Configurator-QP.
1. Click [Connection setup] for [Online] on GX
Configurator-QP.
2. The [Connection setup] is displayed.
3. Set the [PC side] in [Connection setup].
Interface: (RS-232C)
COM setting: COM1 to COM10
Transmission speed: 9.6kbps to 115.2kbps
Interface: USB
When connecting the GOT and PC with serial
When connecting the GOT and PC with USB
4. Set the [PLC side] in [Connection setup].
PLC type: Q series PLC type
Multi PLC specification: None/No.1 to 4
Direct CPU connection, mark the [via GOT
transparent mode] checkbox.
Interface: PLC
Type: Bus
Interface: PLC
Type: Direct coupled
Interface: C24
(For bus connection only)
5. Set the [Module connecting I/O address] in
[Connection setup].
Specify the actual IP address of the module.
6. The screen returns to the [Connection setup]. Click
the [Connection Test] to check if GX Developer has
been connected to the QD75***(QnCPU).
Bus connection
Direct CPU connection
Computer link connection