Mitsubishi Electronics GOT1000 Portable Multimedia Player User Manual


 
18 - 18
18. CNC CONNECTION
18.5 CNC Side Settings
(2) FCU6-EX878 (Coaxial cable)
*1 Set the network type to the PLC to PLC network.
*2 Set as necessary.
*3 Set the station No. not to overlap with that of other units.
*4 Set the station type to the control station.
For details of the parameter setting, refer to the following.
C6/C64/C64T NETWORK INSTRUCTION MANUAL BNP-B2373
Switch layout No. Switch name Settings
1)
Condition setting
switch
Set the operation condition.
SW Description OFF ON
1
Network type
*1
Inter-PC net (PC) Remote I/O net
2
Station type
*4
Normal station (N.ST) Control station (MNG)
3
Used parameter
*2
Common parameters
(PRM)
Default parameter
(D.PRM)
4
Number of stations
*2
(Valid when SW3 is ON)
OFF 8
Sta
tio
n
ON 16
Sta
tio
n
OFF 32
Sta
tio
n
ON 64
Sta
tio
n
5OFFOFFONON
6
B/W total points
*2
(Valid when SW3 is ON)
OFF 2K
poi
nts
ON 4K
poi
nts
OFF 6K
poi
nts
ON 8K
poi
nts
7OFFOFFONON
8 Not used Always OFF
2)
Station number
setting switch
Station number setting
*2*3
(Setting range)
01 to 64: Station number
Other than 01 to 64: Setting error
3)
Setting switch of
group number
Group number setting
Not used, fixed to 0
4)
Setting switch of
network number
Network number setting
*2
(Setting range)
001 to 255: Network number
Other than 001 to 255: Setting error
5)
Mode setting switch
Mode setting
*2
0: Online
1: Cannot be used
2: Offline
3 to F: Test mode
1)
3)
5)
2)
4)
1
8
7
6
5
4
3
2
ON