13. CC-Link CONNECTION (INTELLIGENT DEVICE STATION)
13.4 PLC Side Setting
13 - 27
9
MELSECNET/H
CONNECTION (PLC
TO PLC NETWORK)
10
MELSECNET/10
CONNECTION (PLC
TO PLC NETWORK)
11
CC-Link IE CONTROLLER
NETWORK
CONNECTION
12
CC-Link IE FIELD
NETWORK
CONNECTION
13
CC-Link CONNECTION
(INTELLIGENT DEVICE
STATION)
14
CC-Link
CONNECTION
(Via G4)
15
INVERTER
CONNECTION
16
SERVO AMPLIFIER
CONNECTION
13.4.6 Connecting to CC-Link module
(QnA Series)
This section describes the settings of the GOT and CC-
Link module (QnA Series) in the following case of system
configuration.
POINTPOINTPOINT
CC-Link module (QnA Series)
For details of the CC-Link module (QnA Series), refer
to the following manual.
Control & Communication Link System Master/
Local Module Type AJ61QBT11/A1SJ61QBT11
User's Manual
System configuration
*1 The CC-Link module is mounted on the base unit slot 0.
The Start I/O No. of the CC-Link module is set to "0"
Switch settings of CC-Link module (QnA
Series)
Set for each setting switch.
(1) Station number setting switch
: Necessary : As necessary : Not necessary
(2) Mode setting switch
: Necessary : As necessary : Not necessary
*1
<CC-Link module>
(Use the default value for settings other than the following.)
<GOT> (Use the default value for settings other
than the following.)
Station type : Intelligent device
station
Station No.
: Station No.1
Number of stations occupied
: Exclusive station 1
Transmission speed
: 156kbps
Station type
: Master station
Station No.
: Station No.0
Mode setting : Remote net mode
All connect count
: 1
Transmission speed : 156kbps
■ [Controller Setting] of GT Designer3
■ Setting of the CC-Link communication unit
■ Switch settings of CC-Link module (QnA Series)
■ Parameter setting
Station
number
setting
switch
Description Set value
Setting
necessity at
GOT
connection
Station number setting
(master station)
0 (fixed)
Mode setting
switch
Description Set value
Setting
necessity at
GOT
connection
Mode setting
(Online: Remote net
mode)
0 (fixed)
A
J61QBT11
E
R
R
O
R
R
A
T
E
B
T
E
S
T
1
B RATE
0 156K
1 625K
2 2. 5M
35M
4 10M
ON
MODE
0 : ONLINE (A. R. )
2 : OFFLINE
RUN
ERR.
MST
S MST
LOCAL
CPU R / W
SW
M / S
PRM
TIME
LINE
L RUN
L ERR.
OFF
S MSTM / L
HOLDCLEAR
3 / 41 / 2
SW
1
2
3
4
5
6
7
8
ON
10
8
6
4
2
9
7
5
3
1
NC
DA
NC
(FG)
SLD
NC
NC
NC
DB
DG
STATIO N NO.
10
x
x
156K
625K
2. 5M
5M
10M
TEST
S0
S1
S2
SD
RD
0
1
9
8
7
6
5
4
3
2
0
1
9
8
7
6
5
4
3
2
0
1
9
8
7
6
5
4
3
2
C
D
B
A
9
8
7
6
5
4
3
2
1
0
F
E
1 : ONLINE (RIM )
2 / 31 / 4
AJ61QBT11
(2)
(4)
(1)
(3)
10
8
6
4
2
9
7
5
3
1
NC
DA
NC
(FG)
SLD
NC
NC
NC
DB
DG
A1SJ61QBT11
A
1SJ61QBT11
12345678
O N
STATION NO. MODE
10
x
1
x
B RATE
0 156K
1 625K
2 2. 5M
35M
410M
1
2
3
4
5
6
7
8
M / L
CLR
1/2
S. M
HLD
3/4
SW OFF ON
RUN
ERR.
MST
S MST
LOCAL
CPU R / W
L RUN
L ERR.
SD
RD
SW
M / S
PRM
TIME
LINE
E
R
R
O
R
0
1
9
8
7
6
5
4
3
2
0
1
9
8
7
6
5
4
3
2
0
1
9
8
7
6
5
4
3
2
C
D
B
A
9
8
7
6
5
4
3
2
1
0
F
E
1/4 2/3
A1SJ61QBT11
(2)
(4)
(1)
(3)
10
x
1
x
0
1
9
8
7
6
5
4
3
2
0
1
9
8
7
6
5
4
3
2
MODE
C
D
B
A
9
8
7
6
5
4
3
2
1
0
F
E