22. FA TRANSPARENT FUNCTION
22.2 Compatible Software
22 - 3
17
ROBOT
CONTROLLER
CONNECTION
18
CNC CONNECTION
19
GOT MULTI-DROP
CONNECTION
20
MULTIPLE-GT14, GT12,
GT11, GT10
CONNECTION FUNCTION
21
MULTI-CHANNEL
FUNCTION
22
FA TRANSPARENT
FUNCTION
Connecting the GOT and personal computer with RS-232
(1) When connecting the GOT and PLC in bus connection
The following shows the software and the accessible PLC CPUs.
*1 GX Developer Version 8 or later is required to use the FA transparent function.
GX Developer Version 8.68W or later is required to use the FA transparent function when connecting the QnUDE(H)CPU to the
GOT.
*2 MT Developer (SW6RNC-GSVE) Version 00N or later is required to use the FA transparent function.
*3 MR Configurator (MRZJW3-SETUP221E) Version B1 or later is required to use the FA transparent function.
*4 PX Developer Version 1.09K or later is required to use the FA transparent function.
PX Developer Version 1.18U or later is required to use the FA transparent function when connecting the Q02PHCPU or
Q06PHCPU to the GOT.
*5 Use GX Developer Version 8.30G or later combined with the following GX Configurator version or later to use the FA transparent
function.
GX Configurator-AD : Version 2.03D or later, GX Configurator-DA : Version 2.04E or later
GX Configurator-SC : Version 2.10L or later, GX Configurator-CT : Version 1.23Z or later
GX Configurator-TI : Version 1.22Y or later, GX Configurator-TC : Version 1.21X or later
GX Configurator-AS : Version 1.20W or later, GX Configurator-FL : Version 1.21X or later
GX Configurator-PT : Version 1.20W or later
*6 RT ToolBox2 Version 1.1 or later is required to use the FA transparent function.
*7 GX Configurator-QP Version2.32J or later is required to use the FA transparent function.
*8 MT Works2 Version 1.00A or later is required to use the FA transparent function.
*9 MELSOFT Navigator Version 1.04E or later is required to use the FA transparent function.
*10 GX Works2 Version 1.03D or later is required to use the FA transparent function.
*11 MX Component Version 3.14Q or later is required to use the FA transparent function.
*12 Use MX Component Version 3.14Q or later for MX Sheet.
*13 Start MR Configurator2 with MT Developer2 Version 1.10L or later.
*14 MR Configurator2 Version 1.09K or later is required to use the FA transparent function.
*15 A motion controller is required between the GOT and PLC in bus connection.
*16 MX Component Version 4.00A or later is required to use the FA transparent function.
*17 MX Component Version 4.00A or later is required for MX Sheet to use the FA transparent function.
PLC CPU Software
QCPU (Q mode), C Controller module
MELSOFT Navigator
*9
GX Developer
*1
GX Works2
*10
PX Developer
*4
GX Configurator
*5
-AD/DA/SC/CT/TI/TC/AS/FL/PT
GX Configurator-QP
*7
MX Component
*11
, MX Sheet
*12
Q/QnA/ACPU,
motion controller CPU (A Series)
GX Developer
*1
GX Works2
*11
MX Component
*11
, MX Sheet
*12
Motion controller CPU (Q Series)
MELSOFT Navigator
*9
MT Developer
*2
SW6RN-GSV13P, SW6RN-GSV22P, SW6RN-GSV43P,
SW6RN-GSV54P, SW6RN-DOSCP,
SW6RN-SNETP (for user API)
MR Configurator
*3
MT Works2
*8
, MX Component
*16
, MX Sheet
*17
Robot controller (CRnQ-700)
RT ToolBox2
*6
MELSERVO(MR-J3-B)
*15
MR Configurator
*3
, MR Configurator2
*13
MELSERVO(MR-J4-B)
*15
MR Configurator2
*14