Mitsubishi Electronics GOT1000 Portable Multimedia Player User Manual


 
18 - 20
18. CNC CONNECTION
18.5 CNC Side Settings
(2) Contents of setting
*1 Set as necessary.
*2 Set the station No. not to overlap with that of other units.
For details of the parameter setting, refer to the following.
C6/C64/C64T NETWORK INSTRUCTION MANUAL BNP-B2373
No. Switch name Settings
1)
Condition setting
switch
Set the operation condition.
No. Description
Switch status Setting validity
OFF ON
Master station
(Standby
master station)
Local station
(Standby
master station)
SW1
Station type
*1
Master station/local
station
Standby master station (Valid) (Valid)
SW2 Not used Always OFF - -
SW3 Not used Always OFF - -
SW4
Data link error station
input data status
*1
Clear Hold valid valid
SW4
Number of occupied
stations
*1
OFF 1
Sta
tio
n
OFF 2
Sta
tio
n
ON
3
Sta
tion
ON 4
Sta
tio
n
Invalid valid
SW5 OFF ON ON OFF
SW7 Not used Always OFF - -
SW8 Not used Always OFF - -
2)
Mode setting switch
This switch sets the unit operation status.
No. Name Description
Settability
Master station Local station
0
Online
*1
Automatic online return provided when data link is
enabled
Yes Yes
1 Link with remote I/O net mode Yes No
2
Offline
*1
Data link offline state Yes Yes
3
Line test 1
*1
Line test 1 in offline state Yes No
4
Line test 2
*1
Line test 2 in offline state Yes No
5
Parameter confirmation
test
*1
Checks the parameter details Yes No
6
Hardware test
*1
Test Expansion unit (FCU6-HR865) Yes Yes
7 to F Not usable
3)
Transmission speed
setting switch
This switch sets the unit transmission speed.
No. Description
0
156Kbps
*1
1
625Kbps
*1
2
2.5Mbps
*1
3
5Mbps
*1
4
10Mbps
*1
5 to F Not usable
4)
Setting switch of
station No.
This switch sets the unit station No.
*1*2
(Setting range)
Master station: 00
Local station: 01 to 64
Standby master station: 01 to 64