14. CC-Link CONNECTION (Via G4)
14.5 PLC Side Settings
14 - 13
9
MELSECNET/H
CONNECTION (PLC
TO PLC NETWORK)
10
MELSECNET/10
CONNECTION (PLC
TO PLC NETWORK)
11
CC-Link IE CONTROLLER
NETWORK
CONNECTION
12
CC-Link IE FIELD
NETWORK
CONNECTION
13
CC-Link CONNECTION
(INTELLIGENT DEVICE
STATION)
14
CC-Link
CONNECTION
(Via G4)
15
INVERTER
CONNECTION
16
SERVO AMPLIFIER
CONNECTION
Switch setting of peripheral connection
module
Set the station number setting switch, data link
transmission speed setting switch, and operation
setting DIP switch.
(1) Station number setting switch
: Necessary : As necessary : Not necessary
(2) Data link transmission speed setting switch
: Necessary : As necessary : Not necessary
(3) Mode setting switch
: Necessary : As necessary : Not necessary
(4) RS-232 transmission setting switch
: Necessary : As necessary : Not necessary
*1 The peripheral connection module operates with the baud
rate set in the GOT.
14.5.6 [Controller Setting] of GT Designer3
POINTPOINTPOINT
Precautions when setting peripheral connection
module
(1) mode setting switch
Be sure to set the Operation mode setting switch
to "5" (MELSOFT/connection mode).
(2) RS-232 transmission setting switch
Turn OFF SW1 through SW8 of the RS-232
transmission setting switch.
If any switch of SW1 through SW8 is ON, setting
error will occur (RUN LED turns off).
Station number setting
switch
Description Set value
Setting
necessity at
GOT
connection
AJ65BT-R2N
station number
setting
1 to 64
Data link transmission
speed setting switch
Description Set value
Setting
necessity at
GOT
connection
Data link
transmission
speed setting
0: 156kbps
1: 625kbps
2: 2.5Mbps
3: 5Mbps
4: 10Mbps
Mode setting switch Description Set value
Setting
necessity at
GOT
connection
Mode setting
5 (fixed)
(MELSOFT/
connection
mode)
(1)
2
4
(3) (2)
(4)
RS-232 transmission
setting switch
Setting
switch
Description
Set
value
Setting
necessity at
GOT
connection
SW1
Peripheral
transmission
speed
*1
OFF
(fixed)
SW2
SW3
SW4
SW5
Data
bit length
OFF
(fixed)
SW6
Parity bit
length
OFF
(fixed)
SW7
SW8
Stop bit
length
OFF
(fixed)