Mitsubishi Electronics GOT1000 Portable Multimedia Player User Manual


 
3 - 4
3. ACCESS RANGE FOR MONITORING
3.1 Access Range for Monitoring Stations on Network Systems
Direct CPU connection/computer link connection
(1) When connecting to multiple CPU system
Corresponding to the access range described in Bus connection (1).
(2) When connecting to QCPU (Q mode)/QnACPU
Corresponding to the access range described in Bus connection (2).
(3) When connecting to QCPU (A mode)/AnUCPU
The GOT can monitor the control station and all the normal stations
on the network.
For monitoring devices (other than B and W assigned for the network
parameter) of other stations, the GOT cannot monitor the devices of
the PLC CPU that is the QCPU (Q mode) or QnACPU.
If connected to a relay station, use data link parameter [Effective unit
number for accessing other stations] to designate the unit number
that is connected to the network to be monitored.
(4) When connecting to AnACPU/AnNCPU
Corresponding to the access range described in Bus connection (3).
(5) When connecting to motion controller CPU (Q series), CNC (CNC C70), or robot controller (CRnQ-700)
via direct CPU connection
Monitor the motion controller CPU (Q series), CNC (CNC C70), or robot controller (CRnQ-700) via the following
QCPUs in the multiple CPU system.
*1 The control station and normal station correspond to the master station and local station in the CC-Link IE field network
respectively.
CC-Link connection (intelligent device station), CC-Link connection (via G4)
Only the station connected to the GOT can be monitored.
Monitor accessible range of other stations and setting method of monitor devices Example 6:
When using CC-Link connection (intelligent device station) /CC-Link connection (via G4)
When the station connected to the GOT is in the multiple CPU system, the GOT can monitor CPU No.1 to
No.4.
The GOT cannot monitor other stations.
Controller Relay CPU
Motion controller CPU (Q Series)
Q172HCPU, Q173HCPU QCPU (Q mode)
Q172DCPU, Q173DCPU
QnUCPUCNC (CNC C70) Q173NCCPU
Robot controller (CRnQ-700) Q172DRCPU
GOT
Normal
station
Normal
station
Normal
station
Control
station
*1
*1
GOT
Normal
station
Normal
station
M station
L station
Control
station
Normal
station
Control
station
L station