18 - 24
18. CNC CONNECTION
18.7 Precautions
18.7.4 Ethernet connection
Via network system
GOT with Ethernet communication cannot access the
CNCs in another network via the CNC (network
module, Ethernet module, etc.).
When connecting to multiple GOTs
When connecting two or more GOTs in the Ethernet
network, set each [PLC No.] to the GOT.
18.4.1 Setting communication interface
(Communication settings)
When connecting to the multiple network
equipment (including GOT) in a segment
By increasing the network load, the transmission speed
between the GOT and CNC may be reduced.
The following actions may improve the communication
performance.
• Using a switching hub
• More high speed by 100BASE-TX (100Mbps)
• Reduction of the monitoring points on GOT
Ethernet cable connection
Ethernet cable is so susceptible to noise that you
should wire power cables and electric supply cables
separately. And you need to attach a ferrite core
(attachment) on the control unit side.
For details of the Ethernet cable connection, refer to the
following
C6/C64/C64T NETWORK INSTRUCTION
MANUAL BNP-B2373 IX Connection Function
with GOT
Version of CNC
For MELDAS C6/C64, use NC system software version
D0 or later.
LED1
1 turn
Ferrite
core
Ferrite core
Ethernet
FG cable for Ethernet
GOT