7. COMPUTER LINK CONNECTION
7.5 PLC Side Setting
7 - 25
1
PREPARATORY
PROCEDURES FOR
MONITORING
2
DEVICE RANGE
THAT CAN BE SET
3
ACCESS RANGE
FOR MONITORING
4
HOW TO MONITOR
REDUNTANT
SYSTEM
5
BUS CONNECTION
6
DIRECT
CONNECTION TO
CPU
7
COMPUTER LINK
CONNECTION
8
ETHERNET
CONNECTION
(a) Transmission speed setting (SW09 to SW12)
Set the transmission speed (SW09 to SW12) as
follows.
The transmission speed setting must be consistent
with that of the GOT side.
*1 Only transmission speeds available on the GOT side are
shown.
*2 When the software version of AJ71QC24 (-R2/R4) and
A1SJ71QC24 (-R2) is "L" or earlier, and when 2 devices are
connected to the two interfaces individually, make the setting
so that the total transmission speed of the two interfaces is
within 19200bps.
When the total transmission speed of the two interfaces is
within 19200bps, a controller other than GOT can be
connected to the computer link module.
When only one device is connected to either of the
interfaces, a maximum transmission speed of 19200bps can
be set to the one where the device is connected.In this
instance, set SW09 to SW12 to "OFF" on the other side.
*3 When 3 devices are connected to the two interfaces
individually in the case of AJ71QC24N(-R2/R4),
A1SJ71QC24N(-R2), and A1SJ71QC24N1(-R2), make the
setting so that the total transmission speed of the two
interfaces is within 115200bps (within 230400bps in the case
of A1SJ71QC24N1(-R2)).
When the total transmission speed of the two interfaces is
within 115200bps (within 230400bps in the case of
A1SJ71QC24N1(-R2)), a controller other than GOT can be
connected to the computer link module.
When only one device is connected to either of the
interfaces, a maximum transmission speed of 115200bps
can be set to the one where the device is connected.In this
instance, set SW09 to SW12 to "OFF" on the other side.
*4 This can be set only in the case of AJ71QC24N (-R2/R4),
A1SJ71QC24N (-R2) or A1SJ71QC24N1 (-R2).
(3) Station number switch (for both CH1 and CH2)
*5 The station number switch in the figure is for the AJ71QC24
(N) (-R2/R4).
POINTPOINTPOINT
When the switch setting has been changed
Turn the PLC CPU OFF then ON again, or reset the
PLC CPU.
7.5.3 Connecting computer link
module
POINTPOINTPOINT
Computer link module
For details of the computer link module, refer to the
following manual.
Computer Link Module (Com. link func./Print.
func.) User’s Manual
Switch setting on the computer link module
Set the Mode setting switch, the Transmission
specifications switches and the Station number setting
switches.
Setting
Switch
Transmission speed
*1*2*3
4800
bps
9600
bps
19200
bps
38400
bps
*4
57600
bps
*4
115200
bps
*4
SW09 OFF ON OFF ON OFF ON
SW10 OFF OFF ON ON ON ON
SW11 ON ON ON ON OFF OFF
SW12 OFF OFF OFF OFF ON ON
Station number switch
*5
Contents
Set
value
Set the station number of the
serial communication module
to which an access is made
from the GOT.
0
1
STATION
No.
10
AJ71UC24
(1)
(3)
(2)
A
J71UC24
2 - C / N
2 - P / S
2 - PRO
2 - SIO
4 - C / N
4 - P / S
4 - PRO
4 - SIO
CPUR / W
COM
M . D . M
M . D . L
B0
B1
B2
L 4
L 5
L 6
RUN
2 - SD
2 - RD
2 - NEU
2 - ACK
2 - NAK
4 - NEU
4 - ACK
4 - NAK
4 - SD
4 - RD
L 1
L 2
L 3
MODE
STATION NO.
10
1
SW11
12
13
14
15
16
17
18
21
22
23
24
O N
RS - 422
RS - 485
SDA
SDB
RDA
RDB
SG
FG
NC
RS-232-C
A1SJ71UC24-R2
NEU
ACK
NAK
C/N
NEU
ACK
NAK
C/N
P/S
PRO
SIO
SIO
SW
03
04
05
06
07
08
09
10
11
12
RS-232-C
A1SJ71UC24-R2
MODE
1.FORM1
2.FORM2
3.FORM3
4.FORM4
5.MOFORM
(1)
(2)
A1SJ71UC24-R2,
A1SJ71UC24-PRF,
A1SJ71C24-R2,
A1SJ71C24-PRF
8
0
2
3
5
7
8
0
2
3
5
7
8
9
0
3
4
B
C
D
F
A
1SJ71UC24 - R4
SCAN
SCAN E.
SET E.
SIO E.
ST. DWN
MD / L
NEU
NAK
ACK
C / N
P / S
PRO
SIO
COM
MD
RUN
RD
SD
CPU
SW
01
02
03
04
05
06
07
08
09
10
11
12
10
STATION NO.
1
MODE
SDA
SDB
RDA
RDB
SG
FG
NC
RS - 422 / 485
A1SJ71UC24 - R4
(1)
(3)
(2)
A1SJ71UC24-R4,
A1SJ71C24-R4
PULL
MELSEC A1S
CPU24-R2
STOP
RUN
RESETRESET
L CLR
RUN
ERROR
STOP
RUN
RESETRESET
L CLR
RUN
ERROR
MELSEC A1S
CPU24-R2
MITSUBISHIMITSUBISHI
When the cover is open
When the cover is open
A1SCPUC24-R2
A2CCPUC24, A2CCPUC24-PRF
(1)
(2)
(1)
(3)
(2)