9.4 PLC Side Settings
This section describes the settings of the GOT and
MELSECNET/H network module in the case of system
configuration shown as 9.4.1.
When connecting the MELSECNET/H network module to
the MELSECNET/H network system, specify the
MELSECNET/H Mode or the MELSECNET/H Extended
Mode as a network type.
POINTPOINTPOINT
MELSECNET/H network module
For details of the MELSECNET/H network module,
refer to the following manual.
Q corresponding MELSECNET/H Network
System Reference Manual (PLC to PLC
network)
9.4.1 System configuration
*1 The MELSECNET/H network module is mounted at slot 0 of
the base unit.
The start I/O No. of the MELSECNET/H network module is
set at "0".
*2 The network type must be set according to the number of
assignment of send points for each station.
When the number of assignment is 2000 bytes or less:
MELSECNET/H mode
When the number of assignment is 2000 bytes or more:
MELSECNET/H Extended Mode
POINTPOINTPOINT
When connecting to Q170MCPU
When connected to Q170MCPU, the start I/O No. of
the MELSECNET/H network module is set to "70".
9.4.2 Switch setting of
MELSECNET/H network
module
Set the station number setting switch and mode setting
switch.
<MELSECNET/H network module> *
1
(Use the default value for settings other than the following.)
Station No. : 1
Mode : Online (10Mbps)
Network type : MNET/H mode (Control station)
Network No. : 1
Total stations : 2
Network range assignment *
2
:
MELSECNET/H (PLC to PLC network)
<GOT>
(Use the default value for settings other
than the following.)
LB0000
H
to LB00FF
H
LW0000
H
to LW00FF
H
Network type : MNET/H Mode
Network No. : 1
Station No. : 2
Made Setting : Online (auto,reconnection)
Network range assignment *
2
:
Transmission speed : 10Mbps
LB0100
H
to LB01FF
H
LW0100
H
to LW01FF
H
9.4.4 [Controller Setting] of GT Designer3
9.4.2 Switch setting of MELSECNET/H network module
(1) [Network parameter] of GX Developer
MNG
D.LINK
RD
L ERR.
RUN
T.PASS
SD
ERR.
QJ71LP21-25
0
5
9
4
8
3
7
2
6
1
0
5
9
4
8
3
7
2
6
1
STATION NO.
X10
X1
MODE
0
8
F
7
E
6
D
5
C
4
B
A
3
2
9
1
QJ71LP21
-25
IN
OUT
EXT.PW
+24V
24G
24G
0
5
9
4
8
3
7
2
6
1
0
5
9
4
8
3
7
2
6
1
STATION NO.
X10
X1
MODE
0
8
F
7
E
6
D
5
C
4
B
A
3
2
9
1
IN
OUT
MNG
D.LINK
RD
L ERR.
RUN
T.PASS
SD
ERR.
QJ71LP21S-25
QJ71LP21 S-25
EXT.PW
EXT.PW
+24V
24G
(FG)
MNG
D.LINK
RD
L ERR.
RUN
T.PASS
SD
ERR.
0
5
9
4
8
3
7
2
6
1
0
5
9
4
8
3
7
2
6
1
STATION NO.
X10
X1
MODE
0
8
F
7
E
6
D
5
C
4
B
A
3
2
9
1
QJ71BR11
QJ71BR11
(1)
(2)
(1)
(2)
(1)
(2)
QJ71LP21, QJ71LP21-25 QJ71LP21S-25
QJ71BR11