2. DEVICE RANGE THAT CAN BE SET
2.7 MELSEC-WS
2 - 15
1
PREPARATORY
PROCEDURES FOR
MONITORING
2
DEVICE RANGE
THAT CAN BE SET
3
ACCESS RANGE
FOR MONITORING
4
HOW TO MONITOR
REDUNTANT
SYSTEM
5
BUS CONNECTION
6
DIRECT
CONNECTION TO
CPU
7
COMPUTER LINK
CONNECTION
8
ETHERNET
CONNECTION
(4) When using offset specification
When setting devices using the offset function, the
device values are as follows.
(a) Input(I)
(b) Output(Q)
(c) Logic result(LQ)
(d) Logic input(LI)
(e) EFI input(EI)
(f) EFI output(EQ)
Offset +0 +1 +2 +3 +4 +5 +6 +7 +8 to +15
+0 I1.1 I1.2 I1.3 I1.4 I1.5 I1.6 I1.7 I1.8
Fixed to 0
(OFF)
+16 I2.1 I2.2 I2.3 I2.4 I2.5 I2.6 I2.7 I2.8
+32 I3.1 I3.2 I3.3 I3.4 I3.5 I3.6 I3.7 I3.8
+48 I4.1 I4.2 I4.3 I4.4 I4.5 I4.6 I4.7 I4.8
+64 I5.1 I5.2 I5.3 I5.4 I5.5 I5.6 I5.7 I5.8
+80 I6.1 I6.2 I6.3 I6.4 I6.5 I6.6 I6.7 I6.8
+96 I7.1 I7.2 I7.3 I7.4 I7.5 I7.6 I7.7 I7.8
+112 I8.1 I8.2 I8.3 I8.4 I8.5 I8.6 I8.7 I8.8
+128 I9.1 I9.2 I9.3 I9.4 I9.5 I9.6 I9.7 I9.8
+144 I10.1 I10.2 I10.3 I10.4 I10.5 I10.6 I10.7 I10.8
+160 I11.1 I11.2 I11.3 I11.4 I11.5 I11.6 I11.7 I11.8
+176 I12.1 I12.2 I12.3 I12.4 I12.5 I12.6 I12.7 I12.8
+192 Device range error
Offset +0 +1 +2 +3 +4 +5 +6 +7 +8 to +15
+0 Q1.1 Q1.2 Q1.3 Q1.4 Q1.5 Q1.6 Q1.7 Q1.8
Fixed to 0
(OFF)
+16 Q2.1 Q2.2 Q2.3 Q2.4 Q2.5 Q2.6 Q2.7 Q2.8
+32 Q3.1 Q3.2 Q3.3 Q3.4 Q3.5 Q3.6 Q3.7 Q3.8
+48 Q4.1 Q4.2 Q4.3 Q4.4 Q4.5 Q4.6 Q4.7 Q4.8
+64 Q5.1 Q5.2 Q5.3 Q5.4 Q5.5 Q5.6 Q5.7 Q5.8
+80 Q6.1 Q6.2 Q6.3 Q6.4 Q6.5 Q6.6 Q6.7 Q6.8
+96 Q7.1 Q7.2 Q7.3 Q7.4 Q7.5 Q7.6 Q7.7 Q7.8
+112 Q8.1 Q8.2 Q8.3 Q8.4 Q8.5 Q8.6 Q8.7 Q8.8
+128 Q9.1 Q9.2 Q9.3 Q9.4 Q9.5 Q9.6 Q9.7 Q9.8
+144
Q10.1 Q10.2 Q10.3 Q10.4 Q10.5 Q10.6 Q10.7 Q10.8
+160
Q11.1 Q11.2 Q11.3 Q11.4 Q11.5 Q11.6 Q11.7 Q11.8
+176
Q12.1 Q12.2 Q12.3 Q12.4 Q12.5 Q12.6 Q12.7 Q12.8
+192 Device range error
Offset +0 +1 +2 +3 +4 +5 +6 +7
+0 LQ0.0 LQ0.1 LQ0.2 LQ0.3 LQ0.4 LQ0.5 LQ0.6 LQ0.7
+8 LQ1.0 LQ1.1 LQ1.2 LQ1.3 LQ1.4 LQ1.5 LQ1.6 LQ1.7
+16 LQ2.0 LQ2.1 LQ2.2 LQ2.3 LQ2.4 LQ2.5 LQ2.6 LQ2.7
+24 LQ3.0 LQ3.1 LQ3.2 LQ3.3 LQ3.4 LQ3.5 LQ3.6 LQ3.7
+32 Device range error
Offset +0 +1 +2 +3 +4 +5 +6 +7
+0 LI0.0 LI0.1 LI0.2 LI0.3 LI0.4 LI0.5 LI0.6 LI0.7
+8 LI1.0 LI1.1 LI1.2 LI1.3 LI1.4 LI1.5 LI1.6 LI1.7
+16 LI2.0 LI2.1 LI2.2 LI2.3 LI2.4 LI2.5 LI2.6 LI2.7
+24 LI3.0 LI3.1 LI3.2 LI3.3 LI3.4 LI3.5 LI3.6 LI3.7
+32 Device range error
Offset +0 +1 +2 +3 +8 to +15
+0 EI110 EI111 EI112 EI113
Fixed to 0
+16 EI120 EI121 EI122 EI123
+32 EI130 EI131 EI132 EI133
+48
:
+240
Fixed to 0
+256 EI210 EI211 EI212 EI213
+272 EI220 EI221 EI222 EI223
+288 EI230 EI231 EI232 EI233 Device range error
+302 Device range error
Offset +0 +1 +2 +3 to +15
+0 EQ10 EQ11 EQ12
Fixed to 0
+16
:
+240
Fixed to 0
+256 EQ20 EQ21 EQ22 Device range error
+272 Device range error