PowerPath Checklist - Existing HP-UX Server and Existing Storage System
2-41
HP-UX Installation Checklist
10 Server
Cable additional
HBAs to
switches or
storage system
(cont.)
For a 2-Gbit switch - One of the
following:
• The left LED is green and the
right LED is off, which indicates
that a 1-Gbit SP port is logged
in to the switch port.
• For a DS-xxB2 switch, both
LEDs are green, which
indicates that a 2-Gbit HBA
port is logged in to the switch
port.
• For a DS-xxM2 switch, the left
LED is blue and the right LED
is off, which indicates that a
2-Gbit HBA port is logged in to
the switch port.
For a 2-Gbit switch - One of the
following:
• The left LED is green and the
right LED is off, which indicates
that a 1-Gbit SP port is logged
in to the switch port.
• For a DS-xxB2 switch, both
LEDs are green, which
indicates that a 2-Gbit HBA
port is logged in to the switch
port.
• For a DS-xxM2 switch, the left
LED is blue and the right LED
is off, which indicates that a
2-Gbit HBA port is logged in to
the switch port.
Switch documentation
11 Switches
Zone
For a SAN
❑
Zone the switches to provide a
path from each HBA port (host
initiator) to the appropriate SPs.
For a SAN
❑
Zone the switches to provide a
path from each HBA port (host
initiator) to the appropriate SPs.
Switch management
documentation
❑
Checkpoint - Use switch
management software to verify
the switch connections to the
storage system.
❑
Checkpoint - Use switch
management software to verify
the switch connections to the
storage system.
12 Server
Make target SPs
available
❑
Make sure that each HBA sees
only the targets (SPs) to which it
is zoned with the following HP-UX
commands:
ioscan -fnC disk
insf -e
❑
Verify that each HBA sees only
the targets (SPs) to which it is
zoned with the HP-UX following
commands:
ioscan -fnC disk
insf -e
HP-UX documentation
❑
Verify that HP-UX sees device
entries for all LUNS with the
following HP-UX command:
ioscan -fnC disk
❑
Verify that HP-UX sees device
entries for all LUNS with the
following HP-UX command:
❑
ioscan -fnC disk
❑
Log in as root and restart the
Navisphere Host Agent with the
following HP-UX commands:
/sbin/init.d/agent stop
/sbin/init.d/agent start
❑
Log in as root and restart the
Navisphere Host Agent with the
following HP-UX commands:
/sbin/init.d/agent stop
/sbin/init.d/agent start
CX-Series Server
Software for HP-UX
Installation Guide
Task