EMC 69001166 Portable Media Storage User Manual


 
7-12
EMC Installation Roadmap for CX-Series and FC-Series Storage Systems
Windows Installation Checklists
22 Server With
CX500i Storage
System
Configure
optional CHAP
security
If you configured CHAP security for the storage system, you must configure it for
the server’s iSCSI initiators.
For NIC Initiators
Use Navisphere Manager to enable CHAP on the storage system.
Storage-system setup
guide and Manager
online help
Use Microsoft iSCSI Software Initiator to configure initiator CHAP on the
NIC initiators.
Storage-system setup
guide and Microsoft
documentation
For iSCSI HBA Initiators
Use QLogic SANsurfer to configure initiator CHAP on the HBA initiators.
Storage-system setup
guide and SANsurfer
documentation
Use Navisphere Manager to enable CHAP on the storage system Storage-system setup
guide and Manager
online help
23 Server
Make LUNs
available to
Windows
Prepare the LUNs to receive data by creating partitions on them. Host connectivity guide
or Windows
documentation
24 Windows Server
2003 Server
Install optional
CLARiiON VSS
provider
If you want applications to access SnapView functionality on the storage
system using the VSS framework or other APIs, Install the optional
CLARiiON VSS provider on the server.
Note that Navisphere CLI must be installed on the server.
CX-Series Server
Software for Windows
Installation Guide
25 Server
Test PowerPath
with a license key
If you have a PowerPath license key
Note If your PowerPath license key is not registered, the load balancing policy is
restricted to basic failover.
View the LUNs available to the server using the following PowerPath
command:
powermt display dev=all class=clariion
PowerPath product
guide
Choose one available LUN to receive I/O for the test.
View the paths to the chosen LUN using the following PowerPath
command:
powermt display dev=
x
every=2
where
x
is a pseudo device that represents the chosen LUN.
PowerPath product
guide
Start I/O to the LUN.
Task