EMC 69001166 Portable Media Storage User Manual


 
PowerPath Checklist - New HP-UX Server and Existing Storage System
2-19
HP-UX Installation Checklist
12 CX300, CX400,
CX500, CX600,
CX700, or
FC4700-Series
Storage System
Set properties for
PowerPath (cont.)
From an attached or networked host or
laptop
Use the following Navisphere CLI
commands to set the following
storage-system properties for the
server’s existing HBA existing
ports (initiators):
navicli -h
hostname
storagegroup -sethost
-host
servername
-
failovermode 1
navicli -h
hostname
storagegroup -setpath
-host
servername
-arraycommpath 1
where
hostname
is the IP address or
network name of an SP in the
storage system
servername
is the server’s name
or network address
Go to step 14.
From an attached or networked host or
laptop
Use following Navisphere CLI
commands to set the following
default storage-system properties:
navicli -h
hostname
failovermode 1
navicli -h
hostname
arraycommpath 1
where
hostname
is the IP address or
network name of an SP in the
storage system.
Go to step 14.
Navisphere CLI
reference
13
FC4500
Storage
System
Set properties for
PowerPath
Perform this task
either
across the LAN connected to the
Navisphere portal for the storage
system,
or
from an attached host or a host
networked to an attached host,
or
from a laptop connected to a
storage-system serial port, as
described in the storage-system
setup guide.
Perform this task
either
from an attached host or a host
networked to an attached host,
or
from a laptop connected to a
storage-system serial port, as
described in the storage-system
setup guide.
Across LAN
Use Navisphere Manager’s
Failover Setup Wizard (selected
from the Tools menu on the
toolbar) to set the following
storage-system properties for the
server’s existing HBA ports
(initiators):
Failover mode to 1
Array commpath to Enabled
Navisphere Manager
administrator’s guide
and online help
Task