EMC 69001166 Portable Media Storage User Manual


 
PowerPath Checklist — New Solaris Server and Existing Storage System
5-21
Solaris Installation Checklists
12 Server
Make target SPs
available (cont.)
Checkpoint - Use the inquiry
option of the format command to
verify the paths to the storage
system. Alternate paths will have
a device with an ID of
drive type
unknown
.
Checkpoint - Use the inquiry
option of the format command to
verify the paths to the storage
system. Alternate paths will have
a device with an ID of
drive type
unknown.
Solaris documentation
Note The format command will
display n+1 device entries for
each LUN, where n is the number
of paths to the LUN. One of these
entries is a PowerPath device and
the other n entries are native
devices.
Note The format command will
display n+1 device entries for
each LUN, where n is the number
of paths to the LUN. One of these
entries is a PowerPath device and
the other n entries are native
devices.
13 Storage System
Configure
If the server will use an
existing
Storage Group, use Navisphere
Manager to connect the server to
the Storage Group.
Navisphere Manager
administrator’s guide
and online help
If the server will use a
new
Storage Group, use Navisphere
Manager to create RAID Groups,
bind LUNs, create the Storage
Group, and assign LUNs to the
Storage Group.
Use Navisphere Manager to
connect the server to the Storage
Group.
Reboot the server using the
reboot - - -r command so that
Solaris recognizes the LUNs.
Now the LUNs in the Storage
Group look like any other disks in
the server.
Reboot the server using the
reboot - - -r command so that
Solaris recognizes the LUNs.
Now the LUNs look like any other
disks in the server.
Solaris documentation
Checkpoint - Use the format
command to verify that Solaris
recognizes the LUNs.
If Solaris does not recognize any
LUNs, verify the connection to the
Storage Group.
Checkpoint - Use the format
command to verify that Solaris
recognizes the LUNs.
For an FC4500, disconnect the
computer from the serial port on
the storage system.
For an FC4500, disconnect the
computer from the serial port on
the storage system.
Storage-system setup
guide
Task
With Access Logix Without Access Logix Reference Document