PowerPath Checklist — New Windows Server and New Storage System
7-11
Windows Installation Checklists
19 Storage System
Configure
❑
Use Navisphere Manager to set general storage-system properties. Navisphere Manager
administrator’s guide
and online help
❑
Use Navisphere Manager to create RAID Groups, bind LUNs, create
Storage Groups, and assign LUNs to Storage Groups.
❑
Use Navisphere Manager to connect the server to a Storage Group
❑
Reboot the server so Windows Server 2003 or Windows_2000 recognizes
the LUNs.
Now the LUNs in the Storage Group look like any other disks in the server.
Windows documentation
❑
Checkpoint - Use one of the following ways to verify that PowerPath sees
all the paths to the LUNs:
• PowerPath Administrator (Start > Programs
>
EMC > PowerPath
Administrator)
• PowerPath command
powermt display dev=all class=clariion
If PowerPath does not see the LUNs
• Verify the server’s connection to the Storage Group.
• Verify that you registered your PowerPath license key if you have one.
• Verify that the storage-system properties are as defined in step 15.
PowerPath product
guide
20 Storage System
Set up Event
Monitor
❑
Plan your monitoring configuration. Navisphere Manager
administrator’s guide
and online help
❑
Use Navisphere Manager to set user options, create templates, and set up
your monitoring configuration.
21 CX500i Storage
System
Configure
optional CHAP
security
❑
Use Navisphere Manager to configure CHAP on the storage system, but
do
not
enable it yet.
Storage-system setup
guide and Manager
online help
Task
With Access Logix Reference Document