EMC 69001166 Portable Media Storage User Manual


 
5-18
EMC Installation Roadmap for CX-Series and FC-Series Storage Systems
Solaris Installation Checklists
10 CX300, CX400,
CX500, CX600,
CX700, or
FC4700-Series
Storage System
Set Properties
for PowerPath
Use Navisphere Manager’s
Failover Setup Wizard (selected
from the Tools menu on the
toolbar) to set the following
storage-system properties for the
server’s HBA ports (initiators):
Initiator Type to CLARiiON Open
Failover mode to 1
Array commpath to Enabled
Use the following Navisphere CLI
command to determine the
default storage-system type:
navicli -h
hostname
systemtype
where
hostname
is the IP
address or network name of an
SP in the storage system.
If the default storage-system
system type is
not
3 (CLARiiON
Open), use the following
Navisphere CLI command to set it
to 3:
navicli -h
hostname
systemtype
-config 3
where
hostname
is the IP
address or network name of an
SP in the storage system.
CAUTION The above command
reboots both SPs at the same
time.
Navisphere Manager
administrator’s guide
and online help or
Navisphere CLI
reference
If the server is in a Sun Cluster,
use the following Navisphere CLI
command to set the
unitserialnumber storage-system
property to lun:
navicli -h
hostname
unitserialnumber lun
where
hostname
is the IP
address or network name of an
SP in the storage system.
Go to step 12.
Use the following Navisphere CLI
commands to set the following
storage-system properties:
navicli -h
hostname
failovermode 1
navicli -h
hostname
arraycommpath 1
navicli -h
hostname
unitserialnumber lun (only for
server in a Sun Cluster)
where
hostname
is the IP
address or network name of an
SP in the storage system.
Go to step 12.
Navisphere CLI
reference
Task
With Access Logix Without Access Logix Reference Document