7-20
EMC Installation Roadmap for CX-Series and FC-Series Storage Systems
Windows Installation Checklists
14 FC4500 Storage
System
Set properties for
PowerPath
❑
Connect a computer to the serial
port on the storage system.
❑
Connect a computer to the serial
port on the storage system
Storage-system setup
guide
❑
From the computer connected to
the storage system’s serial port,
use the following Navisphere CLI
commands to set the following
storage-system properties for the
server’s HBA or NIC ports
(initiators):
navicli -np -d
device
storagegroup -sethost -host
servername
-type 3
navicli -np -d
device
storagegroup -sethost -host
servername
-failovermode 1
navicli -np -d
device
storagegroup -sethost -host
servername
-arraycommpath 1
where
device
is the name of the
computer port connected to the
storage-system serial port (for
example, com1).
servername
is the name of the
server with the HBAs.
❑
From the computer connected to
the storage system’s serial port,
use the following Navisphere CLI
command to determine the
default storage-system type:
navicli -np -d
device
systemtype
where
device
is the name of the
computer port connected to the
storage-system serial port (for
example, com1).
If the default storage-system
system type is
not
3 (CLARiiON
Open), use the following
Navisphere CLI command to set
it to 3:
navicli -np -d
device
systemtype -config 3
CAUTION The above command
reboots both SPs at the same
time.
Navisphere CLI
reference
❑
From the computer connected to
the storage system’s serial port,
use the following Navisphere CLI
commands to set the following
default storage-system
properties:
navicli -np -d
device
failovermode 1
navicli -np -d
device
arraycommpath 1
where
device
is the name of the
computer port connected to the
storage-system serial port (for
example, com1).
15 Server
Make target SPs
available
❑
Use the Disk Management tool to
scan for disks.
❑
Use the Disk Management tool to
scan for disks.
Windows documentation
Task
With Access Logix Without Access Logix Reference Document