EMC 69001166 Portable Media Storage User Manual


 
Without EMC Failover Software Checklist - New HP-UX Server and New Storage System
2-57
HP-UX Installation Checklist
7 Storage System
Set properties
Use the following Navisphere CLI commands to set the default failover
mode and array commpath properties with the following commands:
navicli -h
hostname
failovermode 0
navicli -h
hostname
arraycommpath 1
where
hostname
is the IP address or network name of an SP in the storage
system.
Navisphere CLI
reference
8 Storage System
Configure
Use Navisphere Manager to set general storage-system properties. Navisphere Manager
administrator’s guide
and online help
Use Navisphere Manager to create RAID Groups, bind LUNs, create
Storage Groups, and assign LUNs to Storage Groups.
Use Navisphere Manager to connect the server to a Storage Group.
9 Server
Make LUNs
visible
Log in as root and restart the Navisphere Host Agent with the following
HP-UX commands:
/sbin/init.d/agent stop
/sbin/init.d/agent start
CX-Series Server
Software for HP-UX
Installation Guide
Checkpoint - Verify that HP-UX can recognize these LUNs with the
following HP-UX commands:
ioscan -fnC disk
insf -e
If HP-UX does not recognize any LUNs, verify the connection to the
Storage Group.
HP-UX documentation
Verify that HP-UX sees device entries for all LUNS with the following
HP-UX command:
ioscan -fnC disk
If you do not see two paths to each LUN, verify that the
OptionsSupported Autotrespass entry in the Host Agent configuration
file is uncommented or commented as described in step 5.
10 Storage System
Set up Event
Monitor
Plan your monitoring configuration. Navisphere Manager
administrator’s guide
and online help
Use Navisphere Manager to set user options, create templates, and set up
your monitoring configuration.
Task
With Access Logix Reference Document