EMC 69001166 Portable Media Storage User Manual


 
PowerPath Checklist — New AIX Server and New Storage System
1-9
AIX Installation Checklists
13 Switches
Zone
For a SAN
Zone the switches to provide a path from each HBA port (host initiator) to
the appropriate SPs.
Switch management
documentation
If MirrorView is installed, create any required zones for it.
Checkpoint - Use switch management software to verify the switch
connections to the storage system.
14 Server
Make target SPs
available
Execute the following AIX command:
emc_cfgmgr.sh
AIX documentation
Checkpoint - Verify that AIX sees LUNZ devices with the following AIX
command:
lscfg | grep LUNZ
If AIX does not see LUNZ devices
Verify that arraycommpath is set to 1 as described in step 12.
Execute the following AIX command:
emc_cfgmgr.sh
Restart the Navisphere Host Agent or run the Navisphere Server Utility
with the following AIX commands:
Host Agent
/
etc/rc.agent stop
/etc/rc.agent start
Server Utility
/usr/lpp/HOSTUTIL/naviserverutil
CX-Series Server
Software for AIX
Installation Guide
Checkpoint - Use Navisphere Manager’s Connectivity Status dialog box
to verify that each HBA is registered with the storage system.
Navisphere Manager
administrator’s guide
and online help
List the LUNZ devices with the following AIX command:
lscfg | grep LUNZ
AIX documentation
Remove each LUNZ device with the following AIX command:
rmdev -dl hdisk
n
where
n
is the hdisk number for the LUNZ device.
Execute the following AIX command:
emc_cfgmg.sh
Task
With Access Logix Reference Document