EMC 69001166 Portable Media Storage User Manual


 
PowerPath Checklist — Existing Windows Server and Existing Storage System
7-53
Windows Installation Checklists
10 Server
Cable additional
HBAs tor NICs to
Fibre Channel
switches,
network, or
storage-system
data ports (cont.)
Checkpoint - For a network
connection with the server, verify
the storage-system connections
to the network router or switch by
checking the LED(s) for the router
or switch port connected to each
SP port.
Switch documentation
11 Server With a
CX500i Storage
System
Configure
additional server
iSCSI initiator
ports
For NICs
Use Microsoft iSCSI Software
Initiator on the server to configure
the iSCSI initiators for each NIC
port.
N/A Storage-system setup
guide
For iSCSI HBAs
Use QLogic SANsurfer to
configure the network parameters
for each or for each HBA.
12 Fibre Channel
Switches
Zone additional
paths
For a SAN
Zone the Fibre Channel switches
to provide a path from each
additional HBA port (host initiator)
to the SPs.
For a SAN
Zone the Fibre Channel switches to
provide a path from each additional
HBA port (host initiator) to the SPs.
Switch management
documentation
Checkpoint - Use switch
management software to verify
the switch connections to the
storage system.
Checkpoint - Use switch
management software to verify
the switch connections to the
storage system
13 Server
Register
additional HBAs
or NICs with
storage system
Restart the Host Agent or run the
Server Utility, then use the Disk
Management tool to scan for
disks.
Use the Disk Management tool to
scan for disks.
Windows documentation
Checkpoint - Use Navisphere
Manager’s Connectivity Status
dialog box to verify that each HBA
is registered with the storage
system.
Navisphere Manager
administrator’s guide
and online help
Task
With Access Logix Without Access Logix Reference Document