PowerPath Checklist — Existing Linux Server and Existing Storage System
3-33
Linux Installation Checklist
6 FC4500 Storage
System
Set properties for
PowerPath
(cont.)
For existing HBAs
An existing HBA is one that is
registered with the storage system.
❑
From the computer connected to
the storage system’s serial port,
use the following Navisphere CLI
commands to set the following
storage-system properties for the
server’s existing HBA existing
ports (initiators):
navicli -np -d
device
storagegroup -sethost -host
servername
-type 3
navicli -np -d
device
storagegroup -sethost -host
servername -
failovermode 1
navicli -np -d
device
storagegroup -sethost -host
servername
-arraycommpath 1
where
device
is the name of the
computer port connected to the
storage-system serial port (for
example, com1).
servername
is the name of the
server with the HBAs
Navisphere CLI
reference
7Server
Re-install Host
Agent or Server
Utility
❑
Reinstall (reload) the Navisphere
Host Agent or Navisphere Server
Utility.
❑
Reinstall (reload) the Navisphere
Host Agent or Navisphere Server
Utility.
CX-Series Server
Software for Linux
Installation Guide
❑
Start Navisphere Host Agent or
run the Navisphere Server Utility.
❑
Start Navisphere Host Agent or
Navisphere Server Utility.
Task
With Access Logix Without Access Logix Reference Document