EMC 69001166 Portable Media Storage User Manual


 
DMP Checklist — New Windows Server and New Storage System
7-61
Windows Installation Checklists
6Switch
Zone switches
for one path
from server to
storage system
For a SAN
Zone switches so that
only one path
exists between a server and the
storage system.
This provides a path from one host initiator (HBA port) to
only one SP
.
You will need to know the WWPN of a host initiator - available in the
switch’s name server table.
Documentation that
ships with the switches
Reboot Windows. Windows documentation
Checkpoint - Use switch management software to verify that the HBA and
storage system are logged in to the switch as fabric ports, and to verify that
the HBA sees only the target (SP) to which it is zoned.
Documentation that
ships with the switches
7 Storage System
Register one
host initiator
Use the Connectivity Status dialog in Navisphere Manager to register
only
one
host initiator with the storage system.
Navisphere Manager
administrator’s guide
and online help
8 Storage System
Connect host
initiator to
Storage Group
Use Navisphere Manager to connect the host initiator to its Storage Group. Navisphere Manager
administrator’s guide
and online help
Use the Disk Management tool to scan for disks.
If the disks are not visible, scan for them once more.
Windows documentation
9 Server
Install Volume
Manager
Install VERITAS Volume Manager for Windows 2000 on the server.
Install any recommended VERITAS updates.
If the server is running VERITAS Volume Manager 3.1 with Service Pack 1, skip
to step 11.
VERITAS Volume
Manager documentation
10 Server
Install the
CLARiiON DMP
driver
Server is running a version of Volume Manager prior to version 3.1 with
Service Pack 1
Download the CLARiiON DMP driver to the server from Services on the
VERITAS website.
VERITAS Volume
Manager documentation
In the directory where you downloaded the driver, double-click the
install.cmd file to install the driver.
Reboot Windows.
11 Server
Add storage
system to DMP
management
Use VERITAS Enterprise Administrator to turn off Exclude in the array
settings menu for a LUN’s path for the storage system.
VERITAS Volume
Manager documentation
Task
With Access Logix Reference Document