EMC 69001166 Portable Media Storage User Manual


 
6-6
EMC Installation Roadmap for CX-Series and FC-Series Storage Systems
Tru64 UNIX Installation Checklist
Checklist - New Tru64 UNIX Server and New Storage System With
Boot Disk
This checklist is for a new storage system that will contain a Tru64
UNIX boot disk. If you do not want the new storage system to contain
a boot disk, use the procedure that starts on page 6-4.
Task
With Access Logix Reference Document
1 Server
Install HBAs and
cables
Install the Fibre Channel HBAs. HBA documentation
Connect a cable from each host HBA port to a switch
port.
Checkpoint — Verify the server connections to the
switch by checking the LED(s) for the switch port
connected to each HBA port.
For a 1-Gbit switch - LED is green, which indicates that
the HBA is logged in to the switch port.
For a 2-Gbit switch - One of the following:
The left LED is green and the right LED is off, which
indicates that a 1-Gbit SP port is logged in to the
switch port.
For a DS-xxB2 switch, both LEDs are green, which
indicates that a 2-Gbit HBA port is logged in to the
switch port.
For a DS-xxM2 switch, the left LED is blue and the
right LED is off, which indicates that a 2-Gbit HBA
port is logged in to the switch port.
2 Storage System
Set Base UDID
Set the Base UDID (UUID on screen) for the storage
system.
If necessary, you can determine the available UDID
ranges for the server or cluster with the following
command:
wwidmgr -show wwid
Host connectivity guide for Tru64 UNIX
and Tru64 UNIX documentation