EMC 69001166 Portable Media Storage User Manual


 
PowerPath Checklist — New NetWare Server and Existing Storage System
4-15
NetWare Installation Checklists
9 Storage System
Register HBAs
On the server, restart the
Navisphere Host Agent or run the
Navisphere Server Utility.
N/A CX-Series Server
Software for NetWare
Installation Guide
Checkpoint - Use Navisphere
Manager’s Connectivity Status
dialog box to verify that each HBA
is registered with the storage
system.
Navisphere Manager
administrator’s guide
and online help
10 Storage System
Set Properties
for PowerPath
For a CX200, CX300, CX400, CX500,
CX600, CX700, or FC4700-Series
storage system
Use Navisphere Manager’s
Failover Setup Wizard (selected
from the Tools menu on the
toolbar) to set the following
storage-system properties for the
server’s HBA ports (initiators):
Initiator Type to CLARiiON Open
Failover mode to 1
Array commpath to Enabled
Unit Serial Number to LUN
For a CX200, CX300, CX400, CX500,
CX600, CX700, or FC4700-Series
storage system
Use the following Navisphere CLI
command to determine the
default storage-system type:
navicli -h
hostname
systemtype
where
hostname
is the IP
address or network name of an
SP in the storage system.
If the default storage-system
system type is
not
3 (CLARiiON
Open), use the following
Navisphere CLI command to set
it to 3:
navicli -h
hostname
systemtype
-config 3
CAUTION The above command
reboots both SPs at the same
time.
Navisphere Manager
administrator’s guide
and online help or
Navisphere CLI
reference
Use the following Navisphere CLI
commands to set the default
failover mode and array
commpath properties to the
values for PowerPath:
navicli -h
hostname
failovermode 1
navicli -h
hostname
arraycommpath 1
where
hostname
is the IP
address or network name of an
SP in the storage system.
Task
With Access Logix Without Access Logix Reference Document