EMC 69001166 Portable Media Storage User Manual


 
2-20
EMC Installation Roadmap for CX-Series and FC-Series Storage Systems
HP-UX Installation Checklist
13
FC4500
Storage
System
Set properties for
PowerPath (cont.)
From an attached host or networked
host
Use the following Navisphere CLI
commands to set the following
default storage-system properties
for the server’s existing HBA
existing ports (initiators):
navicli -d
device
-h
hostname
storagegroup -sethost
-
failovermode 1
navicli -d
device
-h
hostname
storagegroup -sethost
-arraycommpath 1
where
device
is the storage system’s
name
hostname
is the server’s name or
network address.
From an attached or networked host
Use the following Navisphere CLI
commands to set the following
default storage-system properties:
navicli -d
device
-h
hostname
failovermode 1
navicli -d
device
-h
hostname
arraycommpath 1
where
device
is the storage system’s
name
hostname
is the server’s name or
network address.
Navisphere CLI
reference
From a serially connected laptop
Use the following Navisphere CLI
commands to set the following
default storage-system properties
for the server’s existing HBA
existing ports (initiators):
navicli -np -d
device
storagegroup -sethost -host
servername -
failovermode 1
navicli -np -d
device
storagegroup -sethost -host
servername --
arraycommpath 1
where
device
is the name of the
computer port connected to the
storage-system serial port (for
example, com1).
servername
is the name of the
server with the HBAs.
From a serially connected laptop
Use the following Navisphere CLI
commands to set the following
default storage-system properties:
navicli -np -d
device
failovermode 1
navicli -np -d
device
arraycommpath 1
where
device
is the name of the
computer port connected to the
storage-system serial port (for
example, com1).
Storage-system setup
guide and Navisphere
CLI reference
Task
With Access Logix Without Access Logix Reference Document