EMC 69001166 Portable Media Storage User Manual


 
2-36
EMC Installation Roadmap for CX-Series and FC-Series Storage Systems
HP-UX Installation Checklist
7
CX300, CX400,
CX500, CX600,
CX700, or
FC4700-Series
Storage System
Set properties for
PowerPath
(cont.)
From an attached or networked host or
laptop
Use the following Navisphere CLI
commands to set the following
storage-system properties for the
server’s existing HBA existing
ports (initiators):
navicli -h
hostname
storagegroup -sethost
-host
servername
-
failovermode 1
navicli -h
hostname
storagegroup -setpath
-host
servername
-arraycommpath 1
where
hostname
is the IP address or
network name of an SP in the
storage system
servername
is the server’s name
or network address
From an attached or networked host or
laptop
Use the following Navisphere CLI
commands to set the following
storage-system properties:
navicli -h
hostname
failovermode 1
navicli -h
hostname
arraycommpath 1
where
hostname
is the IP address or
network name of an SP in the
storage system.
Go to step 9.
Navisphere CLI
reference
For a server with unregistered HBAs
Perform this task
either
from an attached host or a host
networked to an attached host,
or
from a laptop connected to the
storage system, as described in the
storage-system initialization or
setup guide.
Use the following Navisphere CLI
commands to set the following
default storage-system properties:
navicli -h
hostname
failovermode 1
navicli -h
hostname
arraycommpath 1
where
hostname
is the IP address
or network name of an SP in the
storage system.
Go step 9.
Task
With Access Logix Without Access Logix Reference Document