EMC 69001166 Portable Media Storage User Manual


 
PowerPath Checklist — New AIX Server and Existing Storage System
1-21
AIX Installation Checklists
You are now ready to set up any optional software, such as SnapView
or MirrorView, on the storage system.
16 Server
Test PowerPath
with a license ke
y
(cont.)
View the output of the powermt
display dev=
x
every=2
command, and verify that
The state of the uncabled
paths becomes “dead.”
I/O continues to the remaining
path(s) to the LUN
,
indicating
that the path failover was
successful, and PowerPath is
working properly.
View the output of the powermt
display dev=
x
every=2
command, and verify that
The state of the uncabled
paths becomes “dead.”
I/O continues to the remaining
path(s) to the LUN
,
indicating
that the path failover was
successful, and PowerPath is
working properly.
PowerPath product
guide
Reconnect the cable that you
disconnected from the HBA.
Reconnect the cable that you
disconnected from the HBA.
If you did not follow the above
steps exactly and caused any
LUNs to trespass, restore the
LUNs to their original state with
the following PowerPath
command:
powermt restore
If you did not follow the above
steps exactly and caused any
LUNs to trespass, restore the
LUNs to their original state with
the following PowerPath
command:
powermt restore
Task