EMC 69001166 Portable Media Storage User Manual


 
Without EMC Failover Software Checklist — New Linux Server and New Storage System
3-49
Linux Installation Checklist
Without EMC Failover Software Checklist
New Linux Server and
New Storage System
Complete the tasks highlighted with grey in the checklist before the
service provider arrives.
Task
With Access Logix Reference Document
1 Server
Install HBAs,
drivers, cables
Install the HBAs. HBA documentation
(see URL on page 3-48)
Connect a cable from each host HBA port to a switch port or an SP port.
Boot host.
Install the HBA driver.
2 Server
Set the HBA
driver
parameters
For a Qlogic HBA, set the SAN Topology value in the HBA BIOS. Host connectivity guide
and HBA documentation
(see URL on page 3-48)
Checkpoint - For a SAN, verify the server connections to the switch by
checking the LED(s) for the switch port connected to each HBA.
For 1-Gbit switch - LED is green, which indicates that the HBA is logged
in to the switch port.
For a 2-Gbit switch - One of the following:
The left LED is green and the right LED is off, which indicates that a
1-Gbit SP port is logged in to the switch port.
For a DS-xxB2 switch, both LEDs are green, which indicates that a
2-Gbit HBA port is logged in to the switch port.
For a DS-xxM2 switch, the left LED is blue and the right LED is off,
which indicates that a 2-Gbit HBA port is logged in to the switch port.
Host connectivity guide
and HBA documentation
(see URL on page 3-48)
3Switches
Zone
Zone the switches to provide a path from each host initiator to an SP. Switch management
documentation
Reboot the server.
Checkpoint - Verify that each HBA sees only the targets (SPs) to which it
is zoned.
4Server
Install Host
Agent or Server
Utility
Install the Navisphere Host Agent or Navisphere Server Utility and the
Navisphere CLI.
CX-Series Server
Software for Linux
Installation Guide
If you installed the Host Agent, edit the agent.config file to add the
following entry if it does not already exist:
device auto auto