1-8
EMC Installation Roadmap for CX-Series and FC-Series Storage Systems
AIX Installation Checklists
9Storage System
Initialize and
install software
enablers
❑
Install the Navisphere Initialization Utility on a
non-AIX
host on the
same
subnet
as the storage-system management ports.
Storage-system setup
guide
❑
Use the Navisphere Initialization Utility to initialize the storage system.
❑
If you have SAN Copy, SnapView, and/or MirrorView software, install their
enablers.
Navisphere Manager
administrator’s guide
and online help
10 Storage System
Cable
❑
Connect the storage system to the switch or HBA ports. Storage-system setup
guide.
❑
Checkpoint - For a SAN, verify the storage-system connections to the
switch by checking the LED(s) for the switch port connected to each SP
port.
For a 1-Gbit switch - LED is green, which indicates that the SP is logged
in to the switch port.
Switch documentation
For a 2-Gbit switch - One of the following:
• The left LED is green and the right LED is off, which indicates that a
1-Gbit SP port is logged in to the switch port.
• For a DS-xxB2 switch, both LEDs are green, which indicates that a
2-Gbit HBA port is logged in to the switch port.
• For a DS-xxM2 switch, the left LED is blue and the right LED is off, which
indicates that a 2-Gbit HBA port is logged in to the switch port.
❑
Cable each SP to the LAN connected to the hosts from which you will
manage the storage system.
Storage-system setup
guide.
11 Storage System
Set up security
❑
Use Navisphere Manager to define a global administrator and domain (if
not already defined) and any additional users.
Navisphere security
administrator’s guide
and Navisphere
Manager online help
12 Storage System
Set properties
for PowerPath
❑
Use the following Navisphere CLI commands to set the storage system’s
default system type, failover mode, and array commpath values:
navicli -h
hostname
systemtype -config 3
navicli -h
hostname
failovermode 1
navicli -h
hostname
arraycommpath 1
where
hostname
is the IP address or network name of an SP in the storage
system.
Note: Setting the array commpath property to 1 (enabled) creates LUNZ
devices.
where
hostname
is the IP address or network name of an SP in the storage
system.
Navisphere CLI
reference
Task
With Access Logix Reference Document