EMC 69001166 Portable Media Storage User Manual


 
PowerPath Checklist - New HP-UX Server and Existing Storage System
2-25
HP-UX Installation Checklist
You are now ready to set up any optional software, such as SnapView
or MirrorView, on the storage system.
19 Server
Test PowerPath
with a license
key (cont.)
View the paths to the chosen LUN
using the following PowerPath
command:
powermt display dev=
x
every=2
where
x
is a device that
represents the chosen LUN.
View the paths to the chosen LUN
using the following PowerPath
command:
powermt display dev=
x
every=2
where
x
is a device that
represents the chosen LUN
PowerPath product
guide
Start I/O to the LUN.
Start I/O to the LUN.
Identify the HBA sending I/O to
LUN by viewing the output of the
powermt display dev=
x
every=2
command, and disconnect the
cable to that HBA.
Identify the HBA sending I/O to
LUN by viewing the output of the
powermt display dev=
x
every=2
command, and disconnect the
cable to that HBA.
View the output of the powermt
display dev=
x
every=2
command, and verify that
The state of the uncabled
path(s) becomes “dead.”
I/O continues to the remaining
path(s) to the LUN
,
indicating
that the path failover was
successful, and PowerPath is
working properly.
View the output of the powermt
display dev=
x
every=2
command, and verify that
The state of the uncabled
path(s) becomes “dead.”
I/O continues to the remaining
path(s) to the LUN
,
indicating
that the path failover was
successful, and PowerPath is
working properly.
Reconnect the cable that you
disconnected from the HBA.
Reconnect the cable that you
disconnected from the HBA.
If you did not follow the above
steps exactly and caused any
LUNs to trespass, restore the
LUNs to their original SP with the
following PowerPath command:
powermt restore
If you did not follow the above
steps exactly and caused any
LUNs to trespass, restore the
LUNs to their original SP with the
following PowerPath command:
powermt restore
20
Server
Make LUNs
available to
HP-UX
Prepare the LUNs to receive data
using the Logical Volume
Manager (LVM).
If HP-UX does not recognize any
LUNs, verify the connection to the
Storage Group.
Prepare the LUNs to receive data
using the Logical Volume
Manager (LVM).
Host connectivity guide
and HP-UX
documentation
Task
With Access Logix Without Access Logix Reference Document