EMC 69001166 Portable Media Storage User Manual


 
PowerPath Checklist — Existing Windows Server and Existing Storage System
7-49
Windows Installation Checklists
7 CX-Series or
FC4700-Series
Storage System
Set properties for
PowerPath
(cont.)
For existing HBAs
An existing HBA is one that is
registered with the storage system.
Use Navisphere Manager’s
Failover Setup Wizard (selected
from the Tools menu on the
toolbar) to set the following
storage-system properties for the
server’s existing HBA ports
(initiators):
Initiator Type to CLARiiON Open
Failover mode to 1
Array commpath to Enabled
Navisphere Manager
administrator’s guide
and online help
8 FC4500 Storage
System
Set properties for
PowerPath
Connect a computer to the serial
port on the storage system.
Connect a computer to the serial
port on the storage system.
Storage-system setup
guide
For new HBAs
From the computer connected to
the storage system’s serial port,
use the following Navisphere CLI
command to determine the
default storage-system type:
navicli -np -d
device
systemtype
where
device
is the name of the
computer port connected to the
storage-system serial port (for
example, com1).
If the default storage-system
system type is
not
3 (CLARiiON
Open), use the following
Navisphere CLI command to set
it to 3:
navicli -np -d
device
systemtype -config 3
CAUTION The above command
reboots both SPs at the same
time.
For any HBAs
From the computer connected to
the storage system’s serial port,
use the following Navisphere CLI
command to determine the
default storage-system type:
navicli -np -d
device
systemtype
where
device
is the name of the
computer port connected to the
storage-system serial port (for
example, com1).
If the default storage-system
system type is
not
3 (CLARiiON
Open), use the following
Navisphere CLI command to set
it to 3:
navicli -np -d
device
systemtype -config 3
CAUTION The above command
reboots both SPs at the same time.
Navisphere CLI
reference
Task
With Access Logix Without Access Logix Reference Document