3-34
EMC Installation Roadmap for CX-Series and FC-Series Storage Systems
Linux Installation Checklist
8Server
Cable additional
HBAs to
switches or
storage system
❑
Cable any additional HBA ports to
the switch connected to the
storage system or to SP ports.
❑
Cable any additional HBA ports to
the switch connected to the
storage system or to SP ports.
Storage-system setup
guide.
❑
Checkpoint - For a SAN, verify
the HBA connections to the
switch by checking the LED(s) for
the switch port connected to each
additional HBA port.
For a 1-Gbit switch - LED is
green, which indicates that the
HBA port is logged in to the
switch port.
For a 2-Gbit switch - One of the
following:
• The left LED is green and the
right LED is off, which
indicates that a 1-Gbit SP port
is logged in to the switch port.
• For a DS-xxB2 switch, both
LEDs are green, which
indicates that a 2-Gbit HBA
port is logged in to the switch
port.
• For a DS-xxM2 switch, the left
LED is blue and the right LED
is off, which indicates that a
2-Gbit HBA port is logged in to
the switch port.
❑
Checkpoint - For a SAN, verify
the HBA connections to the
switch by checking the LED(s) for
the switch port connected to each
additional HBA port.
For a 1-Gbit switch - LED is
green, which indicates that the
HBA port is logged in to the
switch port.
For a 2-Gbit switch - One of the
following:
• The left LED is green and the
right LED is off, which
indicates that a 1-Gbit SP port
is logged in to the switch port.
• For a DS-xxB2 switch, both
LEDs are green, which
indicates that a 2-Gbit HBA
port is logged in to the switch
port.
• For a DS-xxM2 switch, the left
LED is blue and the right LED
is off, which indicates that a
2-Gbit HBA port is logged in to
the switch port.
9Switches
Zone for
additional HBAs
For a SAN
❑
Zone the switches to provide a
path from each additional HBA
port (host initiator) to the SPs.
For a SAN
❑
Zone the switches to provide a
path from each additional HBA
port (host initiator) to the SPs.
Switch management
documentation
❑
Checkpoint - Use switch
management software to verify
the switch connections to the
storage system.
❑
Checkpoint - Use switch
management software to verify
the switch connections to the
storage system.
10 Server
Add Persistent
Bindings
❑
Add persistent bindings to the
HBA driver configuration file.
Note: You need the WWPN of
each SP port for the bindings.
❑
Add persistent bindings to the
HBA driver configuration file.
Note: You need the WWPN of
each SP port for the bindings.
HBA documentation
(see URL on page 3-4)
Task
With Access Logix Without Access Logix Reference Document