EMC 69001166 Portable Media Storage User Manual


 
3-34
EMC Installation Roadmap for CX-Series and FC-Series Storage Systems
Linux Installation Checklist
8Server
Cable additional
HBAs to
switches or
storage system
Cable any additional HBA ports to
the switch connected to the
storage system or to SP ports.
Cable any additional HBA ports to
the switch connected to the
storage system or to SP ports.
Storage-system setup
guide.
Checkpoint - For a SAN, verify
the HBA connections to the
switch by checking the LED(s) for
the switch port connected to each
additional HBA port.
For a 1-Gbit switch - LED is
green, which indicates that the
HBA port is logged in to the
switch port.
For a 2-Gbit switch - One of the
following:
The left LED is green and the
right LED is off, which
indicates that a 1-Gbit SP port
is logged in to the switch port.
For a DS-xxB2 switch, both
LEDs are green, which
indicates that a 2-Gbit HBA
port is logged in to the switch
port.
For a DS-xxM2 switch, the left
LED is blue and the right LED
is off, which indicates that a
2-Gbit HBA port is logged in to
the switch port.
Checkpoint - For a SAN, verify
the HBA connections to the
switch by checking the LED(s) for
the switch port connected to each
additional HBA port.
For a 1-Gbit switch - LED is
green, which indicates that the
HBA port is logged in to the
switch port.
For a 2-Gbit switch - One of the
following:
The left LED is green and the
right LED is off, which
indicates that a 1-Gbit SP port
is logged in to the switch port.
For a DS-xxB2 switch, both
LEDs are green, which
indicates that a 2-Gbit HBA
port is logged in to the switch
port.
For a DS-xxM2 switch, the left
LED is blue and the right LED
is off, which indicates that a
2-Gbit HBA port is logged in to
the switch port.
9Switches
Zone for
additional HBAs
For a SAN
Zone the switches to provide a
path from each additional HBA
port (host initiator) to the SPs.
For a SAN
Zone the switches to provide a
path from each additional HBA
port (host initiator) to the SPs.
Switch management
documentation
Checkpoint - Use switch
management software to verify
the switch connections to the
storage system.
Checkpoint - Use switch
management software to verify
the switch connections to the
storage system.
10 Server
Add Persistent
Bindings
Add persistent bindings to the
HBA driver configuration file.
Note: You need the WWPN of
each SP port for the bindings.
Add persistent bindings to the
HBA driver configuration file.
Note: You need the WWPN of
each SP port for the bindings.
HBA documentation
(see URL on page 3-4)
Task
With Access Logix Without Access Logix Reference Document