PowerPath Checklist — New NetWare Server and Existing Storage System
4-17
NetWare Installation Checklists
11 Server
Make target SPs
available
❑
Scan for LUNs with the following
NetWare command:
scan all luns
❑
Scan for LUNs with the following
NetWare command:
scan all luns
NetWare documentation
❑
Checkpoint - Verify that each
path has a LUNZ with the
following NetWare command:
list devices
❑
Checkpoint - Verify the paths to
each LUN with the following
NetWare command:
list devices
❑
Stop and restart the Navisphere
Host Agent or run the Navisphere
Server Utility.
❑
Stop and restart the Navisphere
Host Agent or run the Navisphere
Server Utility.
CX-Series Server
Software for NetWare
Installation Guide
12 Storage System
Configure
❑
If the server will use an
existing
Storage Group, use Navisphere
Manager to connect the server to
the Storage Group.
Navisphere Manager
administrator’s guide
and online help
❑
If the server will use a
new
Storage Group, use Navisphere
Manager to create RAID Groups,
bind LUNs, create the Storage
Group, and assign LUNs to the
Storage Group.
❑
Use Navisphere Manager to
connect the server to the Storage
Group.
❑
Reboot the server.
❑
Reboot the server.
Task
With Access Logix Without Access Logix Reference Document