PowerPath Checklist — Existing NetWare Server and New Storage System
4-25
NetWare Installation Checklists
13 Switches
Zone additional
HBAs
For a SAN
❑
Zone the switches to provide a path from each additional HBA port (host
initiator) to the SPs.
Switch management
documentation
❑
If SAN Copy, MirrorView, or MirrorView/A is installed, create any required
zones.
❑
Checkpoint - Use switch management software to verify the switch
connections to the storage system.
14 Server
Make target SPs
available
❑
Scan for LUNs with the following NetWare command:
scan all luns
NetWare documentation
❑
Checkpoint - Verify that each path has a LUNZ with the following
NetWare command:
list devices
❑
Restart Navisphere Agent or run Navisphere Server Utility. CX-Series Server
Software for NetWare
Installation Guide
Navisphere Manager
administrator’s guide
and online help
❑
Checkpoint - Use Navisphere Manager’s Connectivity Status dialog box
to verify that each HBA is registered with the storage system.
15 Storage System
Configure
❑
Use Navisphere Manager to set general storage-system properties. Navisphere Manager
administrator’s guide
and online help
❑
Use Navisphere Manager to create RAID Groups, bind LUNs, create
Storage Groups, and assign LUNs to Storage Groups.
❑
Use Navisphere Manager to connect the server to a Storage Group
❑
Reboot the server.
❑
Checkpoint - Verify that PowerPath sees all the paths to the LUNs using
the following PowerPath command:
powermt display dev=all class=clariion
PowerPath product
guide
If PowerPath does not see the LUNs
• Verify the server’s connection to the Storage Group.
• Verify that you registered your PowerPath license key if you have one.
• Verify that the storage-system properties are as defined in step 11.
Task
With Access Logix Reference Document