EMC 69001166 Portable Media Storage User Manual


 
PowerPath Checklist — Existing NetWare Server and New Storage System
4-25
NetWare Installation Checklists
13 Switches
Zone additional
HBAs
For a SAN
Zone the switches to provide a path from each additional HBA port (host
initiator) to the SPs.
Switch management
documentation
If SAN Copy, MirrorView, or MirrorView/A is installed, create any required
zones.
Checkpoint - Use switch management software to verify the switch
connections to the storage system.
14 Server
Make target SPs
available
Scan for LUNs with the following NetWare command:
scan all luns
NetWare documentation
Checkpoint - Verify that each path has a LUNZ with the following
NetWare command:
list devices
Restart Navisphere Agent or run Navisphere Server Utility. CX-Series Server
Software for NetWare
Installation Guide
Navisphere Manager
administrator’s guide
and online help
Checkpoint - Use Navisphere Manager’s Connectivity Status dialog box
to verify that each HBA is registered with the storage system.
15 Storage System
Configure
Use Navisphere Manager to set general storage-system properties. Navisphere Manager
administrator’s guide
and online help
Use Navisphere Manager to create RAID Groups, bind LUNs, create
Storage Groups, and assign LUNs to Storage Groups.
Use Navisphere Manager to connect the server to a Storage Group
Reboot the server.
Checkpoint - Verify that PowerPath sees all the paths to the LUNs using
the following PowerPath command:
powermt display dev=all class=clariion
PowerPath product
guide
If PowerPath does not see the LUNs
Verify the server’s connection to the Storage Group.
Verify that you registered your PowerPath license key if you have one.
Verify that the storage-system properties are as defined in step 11.
Task
With Access Logix Reference Document