EMC Installation Roadmap for CX-Series and FC-Series Storage Systems
AIX Installation Checklists
You are now ready to set up any optional software, such as SnapView
or MirrorView, on the storage system.
15 Server
Test PowerPath
with a license key
(cont.)
Identify the HBA sending I/O to
LUN by viewing the output of the
powermt display dev=
x
every=2
command, and disconnect the
cable to that HBA.
Identify the HBA sending I/O to
LUN by viewing the output of the
powermt display dev=
x
every=2
command, and disconnect the
cable to that HBA.
View the output of the powermt
display dev=
x
every=2
command, and verify that
The state of the uncabled
path(s) becomes “dead.”
I/O continues to the remaining
path(s) to the LUN
,
indicating
that the path failover was
successful, and PowerPath is
working properly.
View the output of the powermt
display dev=
x
every=2
command, and verify that
The state of the uncabled
path(s) becomes “dead.”
I/O continues to the remaining
path(s) to the LUN
,
indicating
that the path failover was
successful, and PowerPath is
working properly.
PowerPath product
guide
Reconnect the cable that you
disconnected from the HBA.
Reconnect the cable that you
disconnected from the HBA.
If you did not follow the previous
steps exactly and caused any
LUNs to trespass, restore the
LUNs to their original SP with the
following PowerPath command:
powermt restore
If you did not follow the previous
steps exactly and caused any
LUNs to trespass, restore the
LUNs to their original SP with the
following PowerPath command:
powermt restore
Task
With Access Logix Without Access Logix Reference Document