EMC 69001166 Portable Media Storage User Manual


 
Without EMC Failover Software Checklist - New HP-UX Server and New Storage System
2-55
HP-UX Installation Checklist
Without EMC Failover Software Checklist - New HP-UX Server and
New Storage System
Complete the tasks highlighted with grey in the checklist before the
service provider arrives.
Task
With Access Logix Reference Document
1 Server
Install HBAs,
drivers, cables
Install the HBAs.
HBA documentation
Connect a cable from each host HBA port to a switch port or an SP port.
Install the HBA driver.
2 Server
Set HBA driver
parameters
Set the HBA driver parameters to the values required for CLARiiON. Host connectivity guide
and HBA
documentation
Reboot the server to complete the installation of the drivers.
Checkpoint — For a SAN, verify the server connections to the switch by
checking the LED(s) for the switch port connected to each HBA port.
For a 1-Gbit switch - LED is green, which indicates that the HBA is logged
in to the switch port.
Switch documentation
For a 2-Gbit switch - One of the following:
The left LED is green and the right LED is off, which indicates that a
1-Gbit SP port is logged in to the switch port.
For a DS-xxB2 switch, both LEDs are green, which indicates that a
2-Gbit HBA port is logged in to the switch port.
For a DS-xxM2 switch, the left LED is blue and the right LED is off, which
indicates that a 2-Gbit HBA port is logged in to the switch port.
3Switches
Zone
For a SAN
Zone the switches to provide a path from each host initiator to an SP.
Switch management
documentation
4 Server
Make target SPs
available
Make sure each HBA sees only the targets (SPs) to which it is zoned with
the following HP-UX commands:
ioscan -fnC disk
insf -e
HP-UX documentation
Checkpoint - Reverify that HP-UX sees device entries for all LUNS with
the following HP-UX command:
ioscan -fnC disk