EMC 69001166 Portable Media Storage User Manual


 
7-62
EMC Installation Roadmap for CX-Series and FC-Series Storage Systems
Windows Installation Checklists
12 Switch
Zone switches
additional paths
from server to
storage system
For a SAN
Zone switches so that
all desired paths
exists between a server and the
storage system.
You will need to know the WWPN of the host initiators - available in the
switch’s name server table.
Documentation that
ships with the switches
Checkpoint - Use switch management software to verify that the HBAs
and storage system are logged in to the switch as fabric ports, and to verify
that each HBA sees only the targets (SPs) to which it is zoned.
13 Storage System
Register
additional host
initiators
Use the Connectivity Status dialog in Navisphere Manager to register the
additional
host initiators with the storage system.
Navisphere Manager
administrator’s guide
and online help
14 Storage System
Connect Storage
Group to
additional host
Use Navisphere Manager to disconnect and then reconnect the server
from its Storage Group.
You can do this from the Host tab of the Storage Group Properties
dialog.
Navisphere Manager
administrator’s guide
and online help
Use the Disk Management tool to scan for disks.
If the disks are not visible, scan for them once more.
Windows documentation
15 Server
Make LUNs
available to both
SPs
Use the Disk Management tool to scan for disks. Windows documentation
16 Server
Verify DMP
installation
Log into VERITAS Enterprise Administrator (VEA). VERITAS Volume
Manager documentation
Click the host name for the server.
Click disks.
Click a device that you know belongs to the CLARiiON storage system.
Click the paths tab for that device. VERITAS Volume
Manager documentation
Verify that the device has primary and secondary paths to it.
Verify the state of the device (enabled or disabled).
Task
With Access Logix Reference Document