2-32
EMC Installation Roadmap for CX-Series and FC-Series Storage Systems
HP-UX Installation Checklist
You are now ready to set up any optional software, such as SnapView
or MirrorView, on the storage system.
19 Server
Test PowerPath
with a license
key (cont.)
❑
View the output of the powermt display dev=
x
every=2 command, and
verify that
• The state of the uncabled path(s) becomes “dead.”
• I/O continues to the remaining path(s) to the LUN
,
indicating that the
path failover was successful, and PowerPath is working properly.
PowerPath product
guide
❑
Reconnect the cable that you disconnected from the HBA.
❑
If you did not follow the above steps exactly and caused any LUNs to
trespass, restore the LUNs to their original SP with the following PowerPath
command:
powermt restore
20 Server
Make LUNs
available to
HP-UX
❑
Prepare the LUNs to receive data using the Logical Volume Manager
(LVM).
If HP-UX does not recognize any LUNs, verify the connection to the
Storage Group.
Host connectivity guide
and HP-UX
documentation
Task
With Access Logix Reference Document