EMC 69001166 Portable Media Storage User Manual


 
3-16
EMC Installation Roadmap for CX-Series and FC-Series Storage Systems
Linux Installation Checklist
9
CX200, CX300,
CX400, CX500,
CX600, CX700,
or FC4700-Series
Storage System
Set properties for
PowerPath
Use Navisphere Manager’s
Failover Setup Wizard (selected
from the Tools menu on the
toolbar) to set the following
storage-system properties for the
server’s existing HBA ports
(initiators):
Initiator Type to CLARiiON Open
Failover mode to 1
Array commpath to Enabled
For an FC4500 storage system, go to
step 11.
Use the following Navisphere CLI
command to determine the
default storage-system type:
navicli -h
hostname
systemtype
where
hostname
is the IP
address or network name of an
SP in the storage system.
If the default storage-system
system type is
not
3 (CLARiiON
Open), use the following
Navisphere CLI command to set it
to 3:
navicli -h
hostname
systemtype
-config 3
CAUTION The above command
reboots both SPs at the same time.
Navisphere Manager
administrator’s guide
and online help and
Navisphere CLI
reference
Use the following Navisphere CLI
commands to set the following
default storage-system
properties:
navicli -h
hostname
failovermode 1
navicli -h
hostname
arraycommpath 1
where
hostname
is the IP
address or network name of an
SP in the storage system.
For an FC4500 storage system, go to
step 11.
Navisphere CLI
reference
Task