5-36
EMC Installation Roadmap for CX-Series and FC-Series Storage Systems
Solaris Installation Checklists
7 FC4500 Storage
System
Set properties for
PowerPath
❑
Connect a computer to the serial
port on the storage system.
❑
Connect a computer to the serial
port on the storage system.
Storage-system setup
guide
For new HBAs
❑
From the computer connected to
the storage system’s serial port,
use the following Navisphere CLI
command to determine the
default storage-system type:
navicli -np -d
device
systemtype
where
device
is the name of the
computer port connected to the
storage-system serial port (for
example, com1).
If the default storage-system
system type is
not
3 (CLARiiON
Open), use the following
Navisphere CLI command to set it
to 3:
navicli -np -d
device
systemtype -config 3
CAUTION The above command
reboots both SPs at the same
time.
For any HBAs
❑
From the computer connected to
the storage system’s serial port,
use the following Navisphere CLI
command to determine the
default storage-system type:
navicli -np -d
device
systemtype
where
device
is the name of the
computer port connected to the
storage-system serial port (for
example, com1).
If the default storage-system
system type is
not
3 (CLARiiON
Open), use the following
Navisphere CLI command to set it
to 3:
navicli -np -d
device
systemtype -config 3
CAUTION The above command
reboots both SPs at the same time.
Navisphere CLI
reference
Task
With Access Logix Without Access Logix Reference Document