EMC 69001166 Portable Media Storage User Manual


 
2-34
EMC Installation Roadmap for CX-Series and FC-Series Storage Systems
HP-UX Installation Checklist
5 Server
Set HBA driver
parameters
Make sure the HBA driver
parameters are set to the values
required for CLARiiON and
PowerPath.
CAUTION Using improper
settings can cause erratic failover
behavior, such as greatly
increased I/O delays.
Make sure the HBA driver
parameters are set to the values
required for CLARiiON and
PowerPath.
CAUTION Using improper
settings can cause erratic failover
behavior, such as greatly
increased I/O delays.
HP-UX Host
connectivity guide and
HBS documentation
6Server
Set
storage-system
type
Edit the Navisphere Host Agent
configuration file agent.config to
comment the OptionsSupported
Autotrespass entry as follows:
# OptionsSupported
Autotrespass
The above entry will set the
initiator type for the HBAs to no
auto trespass when Host Agent is
restarted in the next step.
CX-Series Server
Software for HP-UX
Installation Guide
Log in as root and restart the
Navisphere Host Agent with the
following HP-UX commands:
/sbin/init.d/agent stop
/sbin/init.d/agent start
Log in as root and restart the
Navisphere Host Agent with the
following HP-UX commands:
/sbin/init.d/agent stop
/sbin/init.d/agent start
For an FC4500 storage system, go to
step 8.
From the server, use the following
Navisphere CLI command to set
the system type to no auto
trespass:
For a CX400, CX600, or
FC4700-Series storage system
navicli -h
hostname
systemtype
-config a
where
hostname
is the IP address
or network name of an SP in the
storage system.
Navisphere CLI
reference
Task
With Access Logix Without Access Logix Reference Document