5-12
EMC Installation Roadmap for CX-Series and FC-Series Storage Systems
Solaris Installation Checklists
16 Server
Make LUNs
available to
Solaris
Prepare the LUNs to receive data by
Specifying Solaris mount point names for them
Labeling and partitioning them
Mounting file systems on them
Mounting them to the mount points
Solaris host
connectivity guide or
Solaris documentation
17 Server
Configure
PowerPath for
missing devices
Use the following PowerPath commands to configure PowerPath for any
missing logical devices so all paths to LUNs are visible:
powercf -i or powercf -q
powermt config
PowerPath product
guide
Checkpoint - Use the following PowerPath command to verify that
PowerPath sees all the paths to the LUNs:
powermt display dev=all class=clariion
If PowerPath cannot see all the paths, verify that
You registered your PowerPath license key if you have one.
the storage-system properties are set as defined in step 11.
18 Server
Test PowerPath
with a license
key
If you have a PowerPath license key
Note If your PowerPath license key is not registered, the load balancing policy
is restricted to basic failover.
Stop all applications accessing the storage system and disable user logins
to the server.
View the LUNs available to the server using the following PowerPath
command:
powermt display dev=all class=clariion
PowerPath product
guide
Choose one available LUN to receive I/O for the test.
View the paths to the chosen LUN using the PowerPath following
command:
powermt display dev=
x
every=2
where
x
is a pseudo device that represents the chosen LUN.
Task
With Access Logix Reference Document