7-50
EMC Installation Roadmap for CX-Series and FC-Series Storage Systems
Windows Installation Checklists
8 FC4500 Storage
System
Set properties for
PowerPath
(cont.)
❑
From the computer connected to
the storage system’s serial port,
use the following Navisphere CLI
commands to set the following
default storage-system
properties:
navicli -np -d
device
failovermode 1
navicli -np -d
device
arraycommpath 1
where
device
is the name of the
computer port connected to the
storage-system serial port (for
example, com1).
❑
From the computer connected to
the storage system’s serial port,
use the following Navisphere CLI
commands to set the following
default storage-system
properties:
navicli -np -d
device
failovermode 1
navicli -np -d
device
arraycommpath 1
where
device
is the name of the
computer port connected to the
storage-system serial port (for
example, com1).
For existing HBAs
An existing HBA is one that is
registered with the storage system.
❑
From the computer connected to
the storage system’s serial port,
use the following Navisphere CLI
commands to set the following
storage-system properties for the
server’s existing HBA existing
ports (initiators):
navicli -np -d
device
storagegroup -sethost -host
servername
-type 3
navicli -np -d
device
storagegroup -sethost -host
servername
-failovermode 1
navicli -np -d
device
storagegroup -sethost -host
servername
-arraycommpath 1
where
device
is the name of the
computer port connected to the
storage-system serial port (for
example, com1).
servername
is the name of the
server with the HBAs
Navisphere CLI
reference
Task
With Access Logix Without Access Logix Reference Document