EMC 69001166 Portable Media Storage User Manual


 
7-50
EMC Installation Roadmap for CX-Series and FC-Series Storage Systems
Windows Installation Checklists
8 FC4500 Storage
System
Set properties for
PowerPath
(cont.)
From the computer connected to
the storage system’s serial port,
use the following Navisphere CLI
commands to set the following
default storage-system
properties:
navicli -np -d
device
failovermode 1
navicli -np -d
device
arraycommpath 1
where
device
is the name of the
computer port connected to the
storage-system serial port (for
example, com1).
From the computer connected to
the storage system’s serial port,
use the following Navisphere CLI
commands to set the following
default storage-system
properties:
navicli -np -d
device
failovermode 1
navicli -np -d
device
arraycommpath 1
where
device
is the name of the
computer port connected to the
storage-system serial port (for
example, com1).
For existing HBAs
An existing HBA is one that is
registered with the storage system.
From the computer connected to
the storage system’s serial port,
use the following Navisphere CLI
commands to set the following
storage-system properties for the
server’s existing HBA existing
ports (initiators):
navicli -np -d
device
storagegroup -sethost -host
servername
-type 3
navicli -np -d
device
storagegroup -sethost -host
servername
-failovermode 1
navicli -np -d
device
storagegroup -sethost -host
servername
-arraycommpath 1
where
device
is the name of the
computer port connected to the
storage-system serial port (for
example, com1).
servername
is the name of the
server with the HBAs
Navisphere CLI
reference
Task
With Access Logix Without Access Logix Reference Document