5-20
EMC Installation Roadmap for CX-Series and FC-Series Storage Systems
Solaris Installation Checklists
11
FC4500 Storage
System (cont.)
❑
From the computer connected to
the storage system’s serial port,
use the following Navisphere CLI
commands to set the following
default storage-system
properties:
navicli -np -d
device
failovermode 1
navicli -np -d
device
arraycommpath 1
navicli -np -d
device
unitserialnumber lun (
only
for
server in a Sun Cluster; it
must
left at the default setting for all
other cases)
where
device
is the name of the
computer port connected to the
storage-system serial port (for
example, com1).
Navisphere CLI
reference
12 Server
Make target SPs
available
❑
Add persistent bindings to the
HBA driver configuration file.
❑
Add persistent bindings to the
HBA driver configuration file.
Solaris utilities kit
administrator’s guide
❑
Edit the /kernel/drv/sd.conf file
to add any additional LUNs you
will bind and their targets.
❑
Edit the /kernel/drv/sd.conf file
to add any additional LUNs you
will bind and their targets.
Solaris driver.conf man
page
❑
Reboot the server using the
reboot- --r command so the
HBA can see the targets (SPs).
❑
Reboot the server using the
reboot - - -r command so the
HBA can see the targets (SPs).
Solaris documentation
❑
Checkpoint - Verify that each
HBA sees only the targets (SPs)
to which it is zoned.
❑
Checkpoint - Verify that each
HBA sees only the targets (SPs)
to which it is zoned.
Task