EMC 69001166 Portable Media Storage User Manual


 
5-20
EMC Installation Roadmap for CX-Series and FC-Series Storage Systems
Solaris Installation Checklists
11
FC4500 Storage
System (cont.)
From the computer connected to
the storage system’s serial port,
use the following Navisphere CLI
commands to set the following
default storage-system
properties:
navicli -np -d
device
failovermode 1
navicli -np -d
device
arraycommpath 1
navicli -np -d
device
unitserialnumber lun (
only
for
server in a Sun Cluster; it
must
left at the default setting for all
other cases)
where
device
is the name of the
computer port connected to the
storage-system serial port (for
example, com1).
Navisphere CLI
reference
12 Server
Make target SPs
available
Add persistent bindings to the
HBA driver configuration file.
Add persistent bindings to the
HBA driver configuration file.
Solaris utilities kit
administrator’s guide
Edit the /kernel/drv/sd.conf file
to add any additional LUNs you
will bind and their targets.
Edit the /kernel/drv/sd.conf file
to add any additional LUNs you
will bind and their targets.
Solaris driver.conf man
page
Reboot the server using the
reboot- --r command so the
HBA can see the targets (SPs).
Reboot the server using the
reboot - - -r command so the
HBA can see the targets (SPs).
Solaris documentation
Checkpoint - Verify that each
HBA sees only the targets (SPs)
to which it is zoned.
Checkpoint - Verify that each
HBA sees only the targets (SPs)
to which it is zoned.
Task
With Access Logix Without Access Logix Reference Document