4-36
EMC Installation Roadmap for CX-Series and FC-Series Storage Systems
NetWare Installation Checklists
13
Server
Make LUNs
available to
additional HBAs
❑
Use Navisphere Manager to
disconnect and then reconnect
the server and its Storage Group.
N/A Navisphere Manager
administrator’s guide
and online help
❑
Reboot the server
14 Server
Verify paths to
storage system
❑
Checkpoint - Verify the paths to
each LUN with the following
NetWare command:
list devices
❑
Checkpoint - Verify the paths to
each LUN with the following
NetWare command:
list devices
NetWare
documentation
❑
Checkpoint - Verify that
PowerPath sees the paths to
each LUN using the following
PowerPath command:
powermt display dev=all
class=clariion
❑
Checkpoint - Verify that
PowerPath sees the paths to each
LUN using the following PowerPath
command:
powermt display dev=all
class=clariion
PowerPath product
guide
If PowerPath does not see the
LUNs
• Verify the server’s connection
to the Storage Group.
• Verify that you registered your
PowerPath license key if you
have one.
• Verify that the storage-system
properties are as defined in
step 7 or 8.
If PowerPath does not see the
LUNs
• Verify that you registered your
PowerPath license key if you
have one.
• Verify that the storage-system
properties are as defined in step
7 or 8
For an FC4500 storage system
❑
Disconnect the computer from
the serial port on the storage
system.
For an FC4500 storage system
❑
Disconnect the computer from the
serial port on the storage system.
Storage-system setup
guide
Task