EMC 69001166 Portable Media Storage User Manual


 
1-34
EMC Installation Roadmap for CX-Series and FC-Series Storage Systems
AIX Installation Checklists
9Storage System
Set properties for
PowerPath (cont.)
For any HBAs (cont.)
Use the following Navisphere CLI
commands to set the storage
system’s default failover mode
and array commpath properties:
navicli -h
hostname
failovermode 1
navicli -h
hostname
arraycommpath 1
where
hostname
is the IP
address or network name of an
SP in the storage system.
Note: Setting the array
commpath property to 1
(enabled) creates LUNZ devices.
You will have to remove the LUNZ
devices later in the procedure.
Navisphere CLI
reference
For existing HBAs
Use Navisphere Manager’s
Failover Setup Wizard (selected
from the Tools menu on the
toolbar) to set the storage
system’s initiator type, failover
mode, and array commpath
properties for the server’s HBA
ports (initiators):
Initiator Type to CLARiiON Open
Failover mode to 1
Array commpath to Enabled
Note: Setting the array
commpath property to 1
(enabled) creates LUNZ devices.
You will have to remove the LUNZ
devices later in the procedure.
Navisphere Manager
administrator’s guide
and online help
Task
With Access Logix Without Access Logix Reference Document