EMC 69001166 Portable Media Storage User Manual


 
PowerPath Checklist — New Windows Server and Existing Storage System With Boot Disk
7-29
Windows Installation Checklists
12 Server
Set HBA driver
properties
Reinstall HBA driver.
Reinstall HBA driver. HBA documentation
(see URL on 7-5)
Set the HBA driver parameters to
the values required for
CLARiiON.
CAUTION Using improper
settings can cause erratic failover
behavior, such as greatly
increased I/O delays.
Set the HBA driver parameters to
the values required for
CLARiiON.
CAUTION Using improper
settings can cause erratic failover
behavior, such as greatly
increased I/O delays.
13 Storage System
Set properties for
PowerPath
For a
CX-Series
or FC4700-Series
storage system
Use Navisphere Manager’s
Failover Setup Wizard (selected
from the Tools menu on the
toolbar) to set the following
storage-system properties for the
server’s HBA ports (initiators):
Initiator Type to CLARiiON Open
Failover mode to 1
Array commpath to Enabled
For a
CX-Series
or FC4700-Series
storage system
Use the following Navisphere CLI
command to determine the
default storage-system type:
navicli -h
hostname
systemtype
where
hostname
is the IP
address or network name of an
SP in the storage system.
If the default storage-system
system type is
not
3 (CLARiiON
Open), use the following
Navisphere CLI command to set
it to 3:
navicli -h
hostname
systemtype
-config 3
CAUTION The above command
reboots both SPs at the same
time.
Navisphere Manager
administrator’s guide
and online help or
Navisphere CLI
reference
Use the following Navisphere CLI
commands to set the default
failover mode and array
commpath properties to the
values for PowerPath:
navicli -h
hostname
failovermode 1
navicli -h
hostname
arraycommpath 1
where
hostname
is the IP
address or network name of an
SP in the storage system.
Navisphere CLI
reference
Task
With Access Logix Without Access Logix Reference Document