EMC 69001166 Portable Media Storage User Manual


 
PowerPath Checklist — Existing NetWare Server and Existing Storage System
4-31
NetWare Installation Checklists
7
CX200, CX300,
CX400, CX500,
CX600, CX700,
or FC4700-Series
Storage System
Set properties for
PowerPath
(cont.)
For new HBAs (cont.)
Use the following Navisphere CLI
commands to set the following
default storage-system
properties:
navicli -h
hostname
failovermode 1
navicli -h
hostname
arraycommpath 1
where
hostname
is the IP
address or network name of an
SP in the storage system.
For any HBAs (cont.)
Use the following Navisphere CLI
commands to set the following
default storage-system properties:
navicli -h
hostname
failovermode
1
navicli -h
hostname
arraycommpath 1
where
hostname
is the IP address
or network name of an SP in the
storage system.
Navisphere CLI
reference
For existing HBAs
An existing HBA is one that is
registered with the storage system.
Use Navisphere Manager’s
Failover Setup Wizard (selected
from the Tools menu on the
toolbar) to set the following
storage-system properties for the
server’s existing HBA ports
(initiators):
Initiator Type to CLARiiON Open
Failover mode to 1
Array commpath to Enabled
Navisphere Manager
administrator’s guide
and online help
Task
With Access Logix Without Access Logix Reference Document