![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/2/07/207ea955-b0a5-4690-afdf-8b9461a5122e/207ea955-b0a5-4690-afdf-8b9461a5122e-bg3c9.png)
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-285AUDIX-BD (AUDIX Circuit Pack)
9
AUDIX-BD (AUDIX Circuit Pack)
The AUDIX-BD maintenance object represents a TN566/TN2169 DEFINITY
AUDIX circuit pack combination. For circuit-pack-level problems, see “XXX-BD
(Common Port Circuit Pack)”.
DEFINITY AUDIX consists of a combination of 2 circuit packs that occupy 5 slots
on a port carrier. The tests described in this manual apply only to switch-side
maintenance which tests circuit pack components related to the TDM bus
interface. The AUDIX system has an extensive maintenance strategy that is
described in
DEFINITY AUDIX System Maintenance
, 585-300-110.
MO Name (in
Alarm Log)
Alarm
Level Initial Command to Run
1
1.
UU
is the universal cabinet number (1 for PPN, 2 - 44 for EPNs).
C
is the carrier designation
(A, B, C, D, or E).
SS
is the number of the slot in which the circuit pack resides (01 to 21).
Full Name of MO
AUDIX-BD MINOR test board UUCSS sh AUDIX Circuit Pack
AUDIX-BD WARNING test board UUCSS sh AUDIX Circuit Pack